Kozy-World KWN111 Скачать руководство пользователя страница 11

1 1

Figure 15 - Control  Knob  In  The
OFF  Position

               Figure 16 - Pilot

Manual Control Models

n

LIGHTING

n

INSTRUCTIONS

1 .    S T O P !     R e a d       t h e     s a f e t y
     information  on  the  side of
       heater.
2.  Check  that  gas  supply  to
       heater  is  on.
3.  Push  in  gas  control  knob

        slightly  and  turn clockwise  

 to

       the  OFF position.
4.   Wait five (5) minutes  to  clear
      out   any   air. Then   smell  for
       gas,  including  near  the  floor.
        If      you      smell     gas,    STOP!
       Follow   “B”     in     the     safety
        information  on  the  side of  the
       heater.  If   you   do   not   smell
       gas,  go  to  the  next  step.
5.    Push     in    gas   control   knob
        slightly   and      turn    counter-
       clockwise       to

“PILOT/IGN”

        and  depress  for five(5) seconds

NOTE

:   The  first  time  that  the

h e a t e r       i s     o p e r a t e d     a f t e r
connecting  the  gas  supply ,  the
control  knob  should  be  depressed
for  about  thirty (30) seconds.  This
will   allow  air   to  bleed   from  the  gas
system.
6.    With  control  knob  pressed  in,
       push  down  and   release   the
     ignitor button. This  will  light
        pilot.  If   needed,   keep     pressing
    ignitor button until pilot lights.
7.   Keep  control  knob  depressed
    for  ten (10)  seconds  after
      lighting  pilot. If  pilot  goes  out,
       repeat  steps 5,6  and  7.
8.   To  select  the  desired  heating
       level,  partially   press  down  the
       control  knob  slightly  and  rotate
       counterclockwise  

 . Release  the

        downward  pressure  on  the  knob
       while  continuing to  turn  until  the
       knob  locks at   the desired  setting
      p o s i t i o n .     D o   n o t     o p e r a t e
       between  locked  positions.

n

TO TURN OFF

n

GAS TO APPLIANCE

Shutting  Off  Heater
1.   Turn  control  knob  clockwise

         

  to  the  OFF  position.

2.     Turn  off  all   electric   power   to
       the  appliance  if  service  is  to
        be  performed.
Shutting Off  Burner  Only  (Pilot
Stays  Lit)
Turn control  knob  clockwise 
to  the  PILOT/IGN  position.

n

MANUAL LIGHTING

n

PROCEDURE

1.   Remove  lower  front  panel (see
       Figure 6  page 7)
2.    Follow   steps 1  through  5  under
        

Lighting Instructions

.

3.     With   control   knob   pressed  in,
        strike    match.    Hold   match    to
        pilot until pilot lights.
4.    Keep  control  knob  pressed  in
     for 30  seconds  after lighting
       pilot.  After  30  seconds, release
        control   knob.Follow step 8 under
        

Lighting Instructions

.

5.    Replace  lower  front  panel.

            CAUTION:   Do  not  try  to
adjust  heating  levels  by  using
the  equipment  shutoff  valve.

 Figure 17- Burner  Patterns

            WARNING:   When  running
h e a t e r , s e t     c o n t r o l   k n o b     a t
L O W ,   o r     H I G H     l o c k e d
positions. Never  set  control
k n o b     b e t w e e n     l o c k e d
p o s i t i o n s .   P o o r     c o m b u s t i o n
and  higher  levels  of  carbon
monoxide  may  result.

Slightly  press  in  control  knob  and
turn  counterclockwise               to  the
LOW  or  HIGH  positions(see  Figure
17).

OPERATING     YOUR     HEATER

   n

TO  SELECT

n

             HEATING  LEVEL

Содержание KWN111

Страница 1: ...only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufactur...

Страница 2: ...ARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous 1 This appliance is only for use with the type of gas indicated...

Страница 3: ...r with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSZ223 1 also known as NFPA 54 Available from American National Standards Institute I...

Страница 4: ...ods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for c...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...toff valve l ground joint union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to te...

Страница 7: ...ne of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs At...

Страница 8: ...taching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Страница 9: ...p is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessories page 16 IMPORTANT Install an equipment s...

Страница 10: ...alve see Figure 13 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Fig...

Страница 11: ...ob slightly and rotate counterclockwise Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions...

Страница 12: ...the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 22 Pilot Air Inlet Hole CABINET Air Passageways l Use a vacuum...

Страница 13: ...sed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allo...

Страница 14: ...ked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into w...

Страница 15: ...natural gas company 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Replace control valve 1 Take apart gas tubing and remove foreign matt...

Страница 16: ...en Gas Pressure Is Too Low l Pilot will not stay lit l Burner will have delayed ignition l Heater will not produce specified heat When Gas Quality Is Bad l Pilot will not stay lit l Burner will produc...

Страница 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN KWN111...

Страница 18: ...4Z ML079 01 ML119 01 MB29003 ML060 02 ML083 03 MB28001 ML070 01W DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS pilot Assembly Thermocouple Ignitor Electrod...