Kozy-World KWN111 Скачать руководство пользователя страница 10

1 0

Figure 13-Equipment  Shutoff  Valve

INSTALLATION

CHECKING GAS
CONNECTIONS

   

WARNING: 

  

Test  all  gas piping

and  connections  for  leaks after
installing  or  servicing.   Correct   all
leaks   at   once.

   

WARNING:  Never  use  an  open

flame   to   check   for   a   leak. Apply
a   mixture  of   liquid   soap and
water   to  all   joints.  Bubbles  form-
ing show  a  leak.  Correct  all   leaks
at  once.

Pressure  Testing  Gas  Supply
Piping  System
Test  Pressures  In  Excess  Of
1/2  PSIG  (3.5 K Pa)

1.   Disconnect   appliance   with   its
       appliance       main        gas     valve
     (control valve)   and   equipment
      shutoff    valve   from   gas   supply
     piping  system.  Pressures  in
       excess  of   1/2  psig  will  damage
      heater  regulator.
2.    Cap   off  open   end   of   gas  pipe

where  equipment  shutoff  valve

       was   connected.
3.     Pressurize  supply  piping     sys-

tem  by  either using  compressed
air   or    opening

       main  gas  valve  located  on  or

near  gas  meter.

4.   Check  all  joints  of  gas  supply

piping  system.  Apply  mixture  of
liquid  soap  and  water  to  gas
joints. Bubbles  forming  show

      a  leak.
5.   Correct  all  leaks  at  once.
6.   Reconnect heater and equipment
       shutoff  valve  to  gas supply.  Check

reconnected   fittings  for  leaks.

Test  Pressures  Equal  To or
Less  Than  1/2  PSIG  (3.5 K Pa)

1.   Close equipment  shutoff  valve
       (see Figure 13).
2.   Pressurize  supply  piping  system
       by  either  using  compressed  air
      or   opening    main    gas   valve
      located  on  or  near  gas  meter.
3.   Check  all  joints  from  gas  meter
      to  equipment  shutoff  valve  (see
      Figure   14).   Apply    mixture   of
       liquid  soap and water to  gas joints.
      Bubbles  forming show a leak.
4.   Correct  all  leaks  at  once.

Pressure  Testing  Heater  Gas
Connections

1.  Open  equipment  shutoff  valve
      (see  Figure  13).
2.   Open main  gas  valve  located  on
      or  near gas  meter.
3.   Make    sure    control    knob    of
      heater  is  in  the  OFF position.
4.   Check  all  joints  from  equipment
      shutoff   valve   to   control   valve
      (see  Figure 14 ).  Apply  mixture  of
      liquid   soap    and    water  to   gas
    joints. Bubbles  forming  show
      a  leak.
5.   Correct all leaks at once.
6.  Light    heater    (see   Operating
   Heater,  pages  10  and  11)
     Check   the  rest  of  the   internal
      joints  for  leaks.
7.   Turn  off  heater (see  To  Turn  Off
      Gas  to  Appliance,  page 11)
8.   Replace  lower  front  panel.

OPERATING YOUR HEATER

n

FOR YOUR SAFETY

n

READ BEFORE LIGHTING

A.  When  lighting  the  pilot,  follow
      these  instructions  exactly.
B.  BEFORE  LIGHTING  smell  all
     around   the  appliance  area  for
     gas.  Be  sure  to  smell  next  to
      the  floor  because  some  gas  is
     heavier  than  air  and  will  settle
      on the  floor .

WHAT TO DO  IF YOU SMELL GAS

Do  not  try  to  light any  appliance.

Do not touch any electric switch;

    do not use any phone in your
       building.

Immediately       call      your     gas

    supplier from  a  neighbor’s
       phone.     Follow        the        gas
       supplier’s   instructions.

If     you     cannot    reach     your

    gas  supplier,  call   the  fire
      department.

C.  Use  only  your  hand  to  push  in
     or  turn  the   gas   control  knob.
     Never   use   tools.  If   the   knob
    will  not  push  in  or  turn  by
      hand, don’t  try  to  repair  it, call
     a qualified service technician or
      gas supplier. Force or attempted
    repair may result in  a fire or
      explosion.
D.  Do not use this appliance if any
      p a r t   h a s   b e e n   u n d e r   w a t e r .
    Immediately  call  a  qualified
     service  technician   to   inspect
      the  appliance   and   to   replace
      any  part  of  the  control  system
     and any gas control which has
      been  under  water.

Figure 14 -Checking  Gas  Joints

            WARNING:   If  you  do  not
follow   these  instructions  exactly,
a   fire   or   explosion  may  result
causing property damage personal
injury or loss of  life.

Содержание KWN111

Страница 1: ...only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufactur...

Страница 2: ...ARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous 1 This appliance is only for use with the type of gas indicated...

Страница 3: ...r with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSZ223 1 also known as NFPA 54 Available from American National Standards Institute I...

Страница 4: ...ods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for c...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...toff valve l ground joint union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to te...

Страница 7: ...ne of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs At...

Страница 8: ...taching Mounting Bracket To Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mounting...

Страница 9: ...p is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessories page 16 IMPORTANT Install an equipment s...

Страница 10: ...alve see Figure 13 2 Open main gas valve located on or near gas meter 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Fig...

Страница 11: ...ob slightly and rotate counterclockwise Release the downward pressure on the knob while continuing to turn until the knob locks at the desired setting position Do not operate between locked positions...

Страница 12: ...the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if compressed air is not available Figure 22 Pilot Air Inlet Hole CABINET Air Passageways l Use a vacuum...

Страница 13: ...sed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not fully open 4 Thermocouple connection is loose at control valve 5 Pilot flame is not touching thermocouple This allo...

Страница 14: ...ked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into w...

Страница 15: ...natural gas company 3 Clean ODS pilot see Cleaning page 12 1 Locate and correct all leak s see Checking Gas Connections page 10 2 Replace control valve 1 Take apart gas tubing and remove foreign matt...

Страница 16: ...en Gas Pressure Is Too Low l Pilot will not stay lit l Burner will have delayed ignition l Heater will not produce specified heat When Gas Quality Is Bad l Pilot will not stay lit l Burner will produc...

Страница 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN KWN111...

Страница 18: ...4Z ML079 01 ML119 01 MB29003 ML060 02 ML083 03 MB28001 ML070 01W DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS pilot Assembly Thermocouple Ignitor Electrod...

Отзывы: