SPECIFICATIONS

Btu                                                               25,000                                         25,000
Gas

 Type

                                                       LP Gas                                      Natural Gas

Ignition                                              Automatic or Electronic                    Automatic or Electronic
Manifold   Pressure                                          8"W.C.                                         3"W.C.
Inlet  Gas  Pressure
(In. of water)*
       Maximum                                                   14"                                             10.5"
       Minimum                                                    11"                                                5"
Dimensions, Inches (H

×

W

×

D)

       Stove                                                                   38 3/16

”×

26 3/8

”×

14 1/8

       Carton                                                                  40 1/8

”×

29 5/16

”×

15 5/16

Weight, lbs
       Stove                                                                                     78
       Shipping                                                                                 94
       voltage                                                     120                                            120
       watt

                                          27

                                    27

*For purposes of input adjustment

GFP2516R                               GFN2515R

Delayed   ignition  burner

1.   Manifold  pressure  is  too  low
2.   Burner orifice clogged

1.   Contact   local  gas company
2.    Clean    burner  (see 

Cleaning    and

       Maintenance, 

page 13)

Burner  backfiring  during  combustion

1.   Damaged burner
2.   Gas  regulator  defective

1.   Clean  burner  orifice  (

see  Cleaning

       and  Maintenance

, page 13)

2.   Replace  gas  regulator

Slight   smoke   or   odor   during  initial
operation

1.   Residues  from  manufacturing
       processes
2.   Not enough air
3.   Gas  regulator defective

1.   Problem  will stop after a few hours
      of operation
2.   Check  burner  for  dirt  and  debris.
       If  found, clean  burner (

see Cleaning

       and  Maintenance

, page 13)

3.   Replace  gas  regulator

Dark  residue  on logs  or  inside  of
fireplace

1.   Improper  log  placement
2.   Air holes at burner inlet blocked
3.   Burner flame holes blocked

1.  Properly locate logs  (

see  installing

logs

,  page  22)

2.   Clean out air holes at burner inlet.

Periodically  repeat  as  needed.

3.   Remove blockage or replace burner

Heater produces a clicking/ticking noise
just  after  burner  is  lit  or  shut off

1.    Metal        expanding      while    heating
       or  contracting  while  cooling

1.  This is common with most heaters. If
     noise  is  excessive, contact  qualified
     service person

TROUBLESHOOTING

Continued

Содержание GFN2515R

Страница 1: ...where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion...

Страница 2: ...Information Warnings 3 Air for Combustion and Ventilation 5 Installation 7 Operating heater 10 Cleaning Maintenance 13 Trouble Shooting 15 Specifications 16 Replacement Parts 17 Parts List 18 Install...

Страница 3: ...nd other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert ible for use with other gases 2 Do not place Pro...

Страница 4: ...eck for any shipping damage If fireplace or logs are damaged promptly inform dealer where you bought the fireplace from PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion S...

Страница 5: ...ing if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining ro...

Страница 6: ...Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequa...

Страница 7: ...ating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air A...

Страница 8: ...wells This gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned cop per tubing may be used in certain areas Check your local codes Use pipe of 1 2 d...

Страница 9: ...pply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings...

Страница 10: ...se this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Страница 11: ...ess or to change to the correct minute s then press CLOCK button again time setting is finished 3 When in operation point the remote transmitter to the remote receiver on the burner in a maximum dista...

Страница 12: ...ot smell gas go to the next step 6 Push in gas control slightly and turn counterclockwise to PILOT and depress for five 5 seconds NOTE The first time that the heater is operated after connecting the g...

Страница 13: ...tterns often PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern Figure 18 shows an incorrect pilot flame pattern The incorrect pi lot flame is not touching the thermocouple This will ca...

Страница 14: ...heater before each u se H ave h eat er insp ec t ed yearly by a qualified service person H e a t e r m a y n e e d m o r e f r e q u e n t c l e a n i n g d u e t o excessive lint from carpeting bedd...

Страница 15: ...eedle or similar object to clean ODS pilot This can damage ODS pilot unit W hen pressing the button of ignitor button is pressed there is spark at ODS pilot but no ignition OBSERVED PROBLEM POSSIBLECA...

Страница 16: ...intenance page 13 2 Replace gas regulator Slight smoke or odor during initial operation 1 Residues from manufacturing processes 2 Not enough air 3 Gas regulator defective 1 Problem will stop after a f...

Страница 17: ...unctioning l Type of gas used propane LP or natural gas l Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R...

Страница 19: ...jector NG 1 08 EL025 01 Injector LP 1 09 EB37000R Outlet Tube Assembly 1 1 10 NRV81F1 3 Regulator NG 1 11 NRV81F1 8 Regulator LP 1 12 EB36000R Inlet Tube Assembly 1 1 13 EB38000R ODS Inlet Tube Assemb...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R EL250RHB C EN250RHB C...

Страница 21: ...8 EL019 06RB Back Panel 1 1 9 EL004 06 Regulator Bracket 1 1 10 EL010 01C Upper Decorating Frame 1 1 11 EL011 01 Upper Decorating Wire 1 1 12 EL002 03 01 Upper Mid Louver 1 1 1 1 13 EL006 06 Side Refl...

Страница 22: ...e upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roof at the left side of log 3 Figure 3 l Insert the pinhole on the upper side of log 5 into the pin on th...

Отзывы: