12
n
TO TURN OFF
n
GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burner Only ( pilot stays
lit)
Turn control knob clockwise
to the
PILOT/IGN position.
NOTE:
If power is on, you can operate
the fireplace by transmitter. Press in
and rotate control knob clockwise
to
ELECTRIC position after shutting off the
fireplace.
n
MANUAL LIGHTING
n
PROCEDURE
1. Follow steps 1 through 5 under
Light-
ing Instructions
.
2. With control knob pressed in, strike
match. Hold match to pilot until pilot
lights.
3. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Follow
step 8 under
Lighting Instructions.
4. After completion of the above-mentioned
three steps, the transmitter is kept in a
state of readiness. If the appliance
doesn
’
t working for a period time, just
pull out the plug from the 110V electrical
outlet.
Figure 16 Manual Control
1.Manual turn-off: when the heater is in
operation, press the ING/OFF button to shut
off the heater.
2.Auto turn-off: refer to the second step of
“
Operations of Timing
”
n
OPERATIONS OF
n
TURN-OFF
If power is off, you can operate the fire-
place by manual
1. STOP! Read the safety information on
the plate with heater.
2. Check that gas supply to heater is on.
3. Remove the door on the right panel.
4. Push in gas control knob slightly and
turn clockwise
to the OFF position.
If Control Knob is on ELECTRIC position,
press down the Control Knob and ro-
tate counterclockwise
to OFF
position.
NOTE
:
Knob cannot be turned from
“
PILOT
”
to
“
OFF
”
unless knob is
pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any
air. Then smell for gas, including
near the floor. If you smell gas, STOP!
Follow
“
B
”
in the safety information
on the side of the heater. If you do
not smell gas, go to the next step
6. Push in gas control slightly and turn
counterclockwise
to
“
PILOT
”
and
depress for five (5) seconds.
NOTE
:
The first time that the heater
is operated after connecting the gas
supply , the control knob should be
depressed fo r ab out thirty (3 0)
seconds. This will allow air to
bleed from the gas system.
7. With control knob pressed in, push
down and release the ignitor button.
This will light pilot. If needed, keep
pressing ignitor button until pilot
lights.
8. Keep control knob depressed for
ten (10) seconds after lighting pilot.
If pilot goes out, repeat steps 5, 6
and 7.
9. To turn on main burner partially
press down the control knob slightly
and rotate counterclockwise
. Re-
lease the down ward pressure on
the knob while continuing to turn
until the knob locks at the
“
ON
”
desired setting position. Do not
operate between locked positions.
Manual Control System
For GFN2515R & GFP2516R
We provide the manual control system
just in case of power shortage.
Install battery for Manual Ignitor:
1. Unscrew the ignitor cap.
2. Insert a AAA type battery with its anode
(
“
+
”
) pointing out.
3. Screw the ignitor back cap.
Note: W e recommend that the battery be
taken out of the ignitor when the power sup-
ply gets right.
n
OPERATIONS OF
n
KEY-PRESS LOCKING
1.Key press locking:
when the burner is in operation or the
transmitter is in a state of readiness,
just press LOCK button on the operat-
in g
panel, there will be a
“ ”
symbol on the
LCD. If any button is pressed now, the
burner will not react at all.
2.Key-press unlocking:
when the burner is in a state of key-press
locking, first press
▼
, then press LOCK
button to unlock it (Child proof-See Fig
12)
n
OPERATIONS OF
n
FAN
Th ere are three selec tio ns:
“
AUT O
”
“
MAN
”
and
“
OFF
”
. W hen pushing the
“
FAN
”
button on the
“
AUTO
”
select, the
fan will be controlled by the thermostat
on the fan blower unit. On the
“
MAN
”
select, the fan will be kept in operation.
To stop the operation, push the
“
FAN
”
button to
“
OFF
”
select. (See Fig 12)
n
LIGHTING
n
INSTRUCTIONS