n

TO TURN OFF

n

GAS TO APPLIANCE

Shutting  Off  Heater

Turn  control  knob  clockwise  

 to the

OFF  position.

Shutting   Off   Burner Only  ( pilot  stays
lit)

Turn control  knob  clockwise 

   to the

PILOT/IGN  position.

NOTE: 

If power is on, you can operate

the  fireplace  by  transmitter.    Press  in
and rotate control knob clockwise  

 to

ELECTRIC position after shutting off the
fireplace.

n

MANUAL LIGHTING

n

PROCEDURE

1.   Follow  steps 1  through  5  under  

Light-

ing Instructions

.

2.   With   control   knob   pressed  in,     strike

match.    Hold   match to  pilot until pilot
lights.

3.  Keep  control  knob  pressed  in  for 30

seconds  after lighting pilot.  After  30
seconds, release control knob.  Follow
step  8  under  

Lighting  Instructions.

4. After completion of the above-mentioned

three steps, the transmitter is kept in a
state  of  readiness.  If  the  appliance
doesn

t working for a period time, just

pull out the plug from the 110V electrical
outlet.

Figure 16  Manual  Control

1.Manual  turn-off: when the heater is in
operation, press the ING/OFF button to shut
off the heater.

2.Auto turn-off: refer to the second step of

Operations of Timing

n

OPERATIONS OF

n

TURN-OFF

If power is off, you can operate the fire-
place by manual

1.  STOP!  Read   the  safety  information  on

the  plate with heater.

2.  Check  that  gas  supply  to heater  is  on.
3.  Remove the door on the right  panel.
4.  Push  in  gas  control  knob slightly and

turn clockwise 

  to the  OFF position.

If Control Knob is on ELECTRIC position,
press down the Control Knob and ro-
tate  counterclockwise 

    to  OFF

position.

    

  NOTE

:   

Knob  cannot  be  turned from

PILOT

    to   

OFF

    unless  knob    is

pushed in slightly. Do not force.

5.  Wait five (5) minutes  to  clear out  any

air. Then   smell  for  gas,   including
near the floor. If  you smell  gas, STOP!
Follow   

B

  in  the  safety  information

on  the    side of  the heater.  If  you  do
not    smell gas,  go  to  the  next  step

6. Push   in gas control slightly and    turn

counterclockwise 

   to  

PILOT

  and

depress  for  five (5)  seconds.

      NOTE

:   

The first time that the heater

is  operated  after connecting  the   gas
supply ,  the control  knob  should  be
depressed   fo r    ab out    thirty    (3 0)
seconds.    This  will      allow    air      to
bleed from  the  gas  system.

7.  With  control  knob  pressed  in, push

down  and  release the ignitor button.
This  will  light pilot.   If  needed,   keep
pressing  ignitor    button    until    pilot
lights.

8.   Keep  control   knob  depressed for

ten (10)  seconds  after lighting  pilot.
If  pilot  goes  out, repeat  steps 5, 6
and  7.

9.    To    turn  on  main  burner    partially

press  down  the  control  knob slightly
and  rotate counterclockwise  

 . Re-

lease   the  down ward  pressure  on
the  knob   while  continuing to  turn
until  the   knob  locks at   the  

ON

desired   setting     position. Do     not
operate  between locked  positions.

Manual Control System

For GFN2515R & GFP2516R

We provide the manual control system
just in case of  power shortage.
Install battery for Manual Ignitor:

1.  Unscrew the ignitor cap.
2.  Insert a AAA type battery with its anode

(

+

) pointing out.

3. Screw the ignitor back cap.
Note: W e recommend that the battery be
taken out of the ignitor when the power sup-
ply gets right.

n

OPERATIONS OF

n

KEY-PRESS LOCKING

1.Key press locking:

when  the burner  is  in  operation or the
transmitter  is    in a  state  of  readiness,
just  press LOCK button  on the operat-
in g
panel, there will be a 

“ ”

 symbol on the

LCD. If  any button is pressed now, the
burner will not react at  all.

2.Key-press unlocking:

when the burner is in a state of key-press
locking, first press

, then press LOCK

button to unlock it (Child proof-See Fig
12)

n

OPERATIONS OF

n

FAN

Th ere  are  three  selec tio ns: 

AUT O

MAN

 and 

OFF

. W hen  pushing the

FAN

 button on the 

AUTO

 select, the

fan will be controlled by the thermostat
on the  fan blower  unit. On the 

MAN

select, the fan will  be kept in operation.
To stop the operation, push the 

FAN

button to 

OFF

 select. (See Fig 12)

n

LIGHTING

n

INSTRUCTIONS

Содержание GFN2515R

Страница 1: ...where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion...

Страница 2: ...Information Warnings 3 Air for Combustion and Ventilation 5 Installation 7 Operating heater 10 Cleaning Maintenance 13 Trouble Shooting 15 Specifications 16 Replacement Parts 17 Parts List 18 Install...

Страница 3: ...nd other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert ible for use with other gases 2 Do not place Pro...

Страница 4: ...eck for any shipping damage If fireplace or logs are damaged promptly inform dealer where you bought the fireplace from PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion S...

Страница 5: ...ing if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining ro...

Страница 6: ...Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequa...

Страница 7: ...ating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air A...

Страница 8: ...wells This gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned cop per tubing may be used in certain areas Check your local codes Use pipe of 1 2 d...

Страница 9: ...pply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings...

Страница 10: ...se this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Страница 11: ...ess or to change to the correct minute s then press CLOCK button again time setting is finished 3 When in operation point the remote transmitter to the remote receiver on the burner in a maximum dista...

Страница 12: ...ot smell gas go to the next step 6 Push in gas control slightly and turn counterclockwise to PILOT and depress for five 5 seconds NOTE The first time that the heater is operated after connecting the g...

Страница 13: ...tterns often PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern Figure 18 shows an incorrect pilot flame pattern The incorrect pi lot flame is not touching the thermocouple This will ca...

Страница 14: ...heater before each u se H ave h eat er insp ec t ed yearly by a qualified service person H e a t e r m a y n e e d m o r e f r e q u e n t c l e a n i n g d u e t o excessive lint from carpeting bedd...

Страница 15: ...eedle or similar object to clean ODS pilot This can damage ODS pilot unit W hen pressing the button of ignitor button is pressed there is spark at ODS pilot but no ignition OBSERVED PROBLEM POSSIBLECA...

Страница 16: ...intenance page 13 2 Replace gas regulator Slight smoke or odor during initial operation 1 Residues from manufacturing processes 2 Not enough air 3 Gas regulator defective 1 Problem will stop after a f...

Страница 17: ...unctioning l Type of gas used propane LP or natural gas l Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R...

Страница 19: ...jector NG 1 08 EL025 01 Injector LP 1 09 EB37000R Outlet Tube Assembly 1 1 10 NRV81F1 3 Regulator NG 1 11 NRV81F1 8 Regulator LP 1 12 EB36000R Inlet Tube Assembly 1 1 13 EB38000R ODS Inlet Tube Assemb...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R EL250RHB C EN250RHB C...

Страница 21: ...8 EL019 06RB Back Panel 1 1 9 EL004 06 Regulator Bracket 1 1 10 EL010 01C Upper Decorating Frame 1 1 11 EL011 01 Upper Decorating Wire 1 1 12 EL002 03 01 Upper Mid Louver 1 1 1 1 13 EL006 06 Side Refl...

Страница 22: ...e upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roof at the left side of log 3 Figure 3 l Insert the pinhole on the upper side of log 5 into the pin on th...