24 VENTING

Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces

#SP-34 LE & MV R.5 January 2020

7.0  VENTING

7.1  Approved Vent Systems

This appliance is equipped for use with a 4” exhaust by 6-5/8” air 

intake co-axial vent pipe system. 
This appliance is approved for use with Kozy Heat 4” x 7” #700 Series 

Flexible Direct Vent system (horizontal terminations only). Refer to 

Section 7.8 #700-2 Series Direct Vent Termination Kit(s) on page 30 

for venting components and installation instructions.
This appliance is approved for use with manufacturers (horizontal and 

vertical terminations): American Metal Products (Ameri-Vent), BDM, 

ICC, Metal Fab*, Olympia Chimney Supply, Inc., Selkirk, and Simpson 

DuraVent.
*WHEN INSTALLING METAL FAB VENT SYSTEM with this appliance 

an adapter must be used. Use adapter part number 4DDA.

The following termination caps are not allowed: Metal Fab 4DHTE; 

Olympia VDV-HSC04; Simpson Duravent 46DVA-HRCS, 46DVA-HSC, 

46DVA-SNK14, 46DVA-SNK36, 46DVA-H2, 46DVA-H2-SNK14, 46DVA-

H2-SNK36.

This appliance can be adapted to use 4” diameter aluminum flexible 

pipe when used in combination with an existing minimum 7” ID Class 

A metal chimney. See Section 7.6 Class A Chimney/Masonry Chimney 

Conversion on page 28.
This appliance can be adapter to use 3” x 3” flexible co-linear vent 

pipes when used in combination with an existing minimum 6” x 8” ID 

masonry or 7” ID Class A metal chimney. See Section 7.7 Coaxial to Co-

Linear Chimney Conversion on page 29.
Refer to the vent manufacturer’s installation manual for complete 

installation instructions. Vent installation must conform with venting 

requirements and restrictions as outlined in this manual.

7.2  Venting Requirements

Consult the local and national installation codes to assure adequate 

combustion and ventilation air is available. Venting requirements 

apply to both natural gas and propane.
NOTE: Wall thimble products that comply with the required clearance 

to combustibles must be installed for all horizontal vent runs that pass 

through interior or exterior walls. These wall thimble products may be 

insulated using unfaced insulation products listed as noncombustible 

per ASTM E 136.
NOTE: Attic insulation shields may be insulated using unfaced 

insulation products listed as noncombustible per ASTM E 136.

• 

Flame height and appearance will vary depending upon venting 

configuration and the type of fuel used.

• 

Refer to the vent manufacturer’s installation manual for 

complete installation instructions. Vent installation must 

conform with venting requirements and restrictions as outlined 

in this manual.

• 

The vertical vent heat shield is required for all vent installations. 

The horizontal vent heat shield must be installed when 

incorporating minimum horizontal venting. See Section 7.10 

Vent Heat Shield Assembly Installation on page 28.

• 

Provide a means for visually checking the vent connection to the 

appliance after the fireplace is installed.

• 

A minimum of 1” (25mm) clearance on all sides of the vertical 

pipe must be maintained. 

• 

A minimum of 1” (25mm) clearance on the top, sides, and bottom 

of the horizontal vent pipes must be maintained.

7.3  Use of Elbows

• 

MAXIMUM NUMBER OF 90° ELBOWS: 5

• 

For each additional 90° elbow used after the first elbow, 3’ (91.4 

cm) must be subtracted from maximum venting allowed. 

• 

For each 45° elbow used, 1½’ (457mm) must be subtracted from 

maximum venting allowed. 

• 

(2) 45° degree elbows may be used in place of (1) 90° elbow.

7.4  Restrictor Plate Assembly 

and Installation

Burner flame appearance and characteristics are affected by altitude, 

fuel quality, venting configuration, and other factors. To achieve 

desirable flame appearance, the vent exhaust may be restricted by 

the restrictor plate (included in components packet).
The restrictor plate is shipped with all inner rings intact, and when 

installed, provides the most vent restriction. There are (2) inner rings 

that can be knocked out. The innermost ring knocked out will create 

less restriction, and the outer most ring knocked out will create the 

least amount of restriction.
Section 11.2.2 Vent restriction (after installation) on page 47 

outlines restriction recommendations depending on burner 

flame appearance, and instructions on installation after venting is 

completed. 

RESTRICTOR PLATE

REMOVE INNER MOST CIRCLE

TO CREATE LESS RESTRICTION

REMOVE ALL INNER RINGS FOR 

THE LEAST RESTRICTION

BEND TABS TO APPROX. 80˚ ANGLES TO CREATE 

TENSION TO HOLD ITSELF IN PLACE WHEN INSTALLED

Figure 7.1, Restrictor Assembly and Installation

SLIDE RESTRICTOR INTO EXHAUST PIPE ON TOP OF FIREPLACE

WITH THE TABS POINTING TOWARDS YOU PRIOR TO ATTACHING VENTING

Содержание SP-34-LE

Страница 1: ...or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless...

Страница 2: ......

Страница 3: ...________________________________________________________________ ____________________________________________________________________________________________________________________ CON GRAT ULAT ION...

Страница 4: ......

Страница 5: ...1 Vertical Vent Cap Termination 22 6 2 Minimum Termination Clearances 23 7 0 VENTING 24 7 1 Approved Vent Systems 24 7 2 Venting Requirements 24 7 3 Use of Elbows 24 7 4 Restrictor Plate Assembly and...

Страница 6: ......

Страница 7: ...eriod a battery operated carbon monoxide detector with an alarm shall be installed 1 3 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provi...

Страница 8: ...ocal authorities or codes having jurisdiction in your area regarding derate guidelines 2 1 1 1 US Installations Refer to the American Gas Association guidelines for the gas designed appliances deratin...

Страница 9: ...y Heat Fireplaces SPECIFICATIONS 9 2 3 Appliance Dimensions Figure 2 1 Appliance Dimensions 51 8 131mm 307 8 786mm 13 342mm 28 711mm 34 864mm 7 198mm 20 519mm 333 8 848mm 14 356mm TOP VIEW LEFT SIDE F...

Страница 10: ...viduals If the barrier becomes damaged the barrier shall be replaced with Hussong Mfg s barriers for this appliance IMPORTANT Consider the height of hearth finish material when building a fireplace pl...

Страница 11: ...wo studs eliminating the need for any additional framing Please be aware of the large amount of heat this fireplace will produce when determining a location 3 2 Floor Support and Protection Floor prot...

Страница 12: ...E Thenailingtabsonbothsidesoftheapplianceallowinstallations for a flush mount 1 2 13mm facing material or 5 8 16mm facing material CAUTION Never permanently remove these assemblies from the fireplace...

Страница 13: ...to fireplace enclosure top 12 305mm Appliance sides to adjacent sidewall 4 1 2 114mm Fireplace enclosure floor to 3 4 19mm trim 33 1 2 108mm Mantel 6 152mm deep from fireplace enclosure floor 37 940m...

Страница 14: ...to support the added weight of the masonry construction above the fireplace If installing optional fan assembly SP 028 it is easier to install before unit installation Please refer to Section 9 3 SP 0...

Страница 15: ...e maintained 1 Measure from floor level of the fireplace to the center of where the vent pipe will penetrate the wall Elbows listed with approved vent systems for this appliance vary in vertical lengt...

Страница 16: ...ation A outdoor covered fireplace installation allows a fireplace to be installed in an outdoor covered area where the appliance is protected from direct precipitation Follow the instructions and illu...

Страница 17: ...tion Minimum weatherproof overhang in front and sides M i n i m u m w e a t h e r p r o o f o v e r h a n g i n f r o n t a n d s i d e s Minimum weatherproof overhang in front and sides M i n i m u m...

Страница 18: ...2mm above the appliance to a maximum 6 152mm depth of a non combustible mantel Follow projection 1 25mm up for every 1 25mm deeper 4 1 2 Adjacent Sidewall Requirements The adjacent sidewall must be 4...

Страница 19: ...CING AND FINISHING 19 Figure 4 1 Clearances to Combustibles 14 356mm 35 895mm 42 1067mm 37 940mm 33 851mm 19mm 6 152mm 1 25mm 4 108mm 12 305mm TRIM 12mm COMBUSTIBLE FACING MATERIAL ALLOWED 14 356mm 42...

Страница 20: ...screen lift the screen up and out of slots 4 2 2 Overlay Designs SP34 POL SP34A POL 1 If installed remove the safety barrier screen 2 Center the overlay over the safety screen 3 Locate the 4 tabs on...

Страница 21: ...re Requirements SP 34 LE Electronic Gas Pressure Natural Gas Propane Minimum Inlet Pressure 5 WC 1 25 kPa 7 WC 1 74 kPa recommended 12 WC 2 99 kPa recommended Maximum Inlet Pressure 10 5 WC 2 62 kPa 1...

Страница 22: ...0 30 Over 6 12 to 7 12 1 25 0 38 Over 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1...

Страница 23: ...building or the combustion air inlet to any other appliance 12 30cm 9 23cm K Clearance to mechanical air supply inlet 6 1 83m 3 91cm above if within 10 3m horizontally Massachusetts 10 3m L Clearance...

Страница 24: ...g unfaced insulation products listed as noncombustible per ASTM E 136 Flame height and appearance will vary depending upon venting configuration and the type of fuel used Refer to the vent manufacture...

Страница 25: ...rtical vent heat shield must be installed for every vent configuration See Section 7 9 on page 32 i Minimum Maximum Vertical Venting 3 914mm minimum vertical length 50 15 24m maximum vertical length t...

Страница 26: ...Vertical Rise Minimum Horizontal Run Maximum Horizontal Run 9 228mm minimum vertical rise 90 horizontal elbow 6 152mm minimum horizontal run 10 3m maximum horizontal run termination cap See Figure 7...

Страница 27: ...ical and maximum horizontal combination venting the vent terminations must be within the shaded area in Figure 7 2 The vertical vent heat shield must be installed for every vent configuration See Sect...

Страница 28: ...7 8 Metalbestos 8 American Metals 6 Jackes Evans 7 8 Jackes Evans 8 Air Jet 6 Hart Cooley 7 8 Hart Cooley 8 Metal Fab 6 Pro Jet 7 8 Pro Jet 6 7 American Metals 6 7 Metal Fab 6 Air jet 7 6 1 4 Flex Pi...

Страница 29: ...eld assembly must be installed when incorporatingminimumhorizontalventingoffthetopoftheappliance IMPORTANT Careshouldbetakenwheninstallingflexiblepipetoavoid a tight bend that may cause abrasion or da...

Страница 30: ...nsulation products listed as non combustible per ASTM E 136 3 Apply a liberal bead of exterior sealant around outer edge of termination box A Place assembly through the wall pass through in exterior w...

Страница 31: ...he 1 25mm top required clearance Hand bend the 6 tabs on the sides and bottom of the wall pass through Repeat for the other section 2 From the interior install one section of the wall pass through Sec...

Страница 32: ...installation 2 Align the 2 slots on the vertical heat shield flanges with corresponding screw holes located in front of the flue outlet on the top of the fireplace 3 Secure the vertical vent heat shie...

Страница 33: ...ss panel 1 Locate 2 spring loaded latches securing the glass assembly at the bottom of the firebox 2 Pull the spring loaded latches out and down to release the bottom of the glass assembly 3 Life glas...

Страница 34: ...log SP34 1A on the back log plate 2 Align the holes in log SP34 2A with the mounting pins on the left front log plate Push log down to seat 3 Align the holes in log SP34 3A with the mounting pins on t...

Страница 35: ...ebox floor 13 Lift the control board out of the firebox being careful not to damage the sealing gasket underneath 8 3 2 Control Board Installation 1 Place control board in the firebox aligning the hol...

Страница 36: ...operational control using low voltage wires not included It is optional to disable the main ON OFF rocker switch operating the main burner by disconnecting the wires from the control module Figure 9 1...

Страница 37: ...Switch PILOT BURNER PILOT IGNITER FLAME SENSOR APPLIANCE GROUND STAR MALE END BATTERY PACK IPI CPI SWITCH MAIN ON OFF SWITCH 886 PROFLAME PILOT BURNER PILOT IGNITER FLAME SENSOR APPLIANCE GROUND STAR...

Страница 38: ...ERMOCOUPLE THERMOPILE PILOT PIEZO WIRE ASSEMBLY not included Attach gas valve connectors to the wall switch thermostat wires connect to top and bottom terminals marked TH and TP TH on gas valve Figure...

Страница 39: ...kit includes 1 Fan assembly 2 Philips head screws black 1 Temperature control switch with magnet attached 1 Speed control box with cord 1 Before unit installation remove the back access panel 4 screw...

Страница 40: ...r switch Press the ON OFF rocker switch to OFF 5 Locate the manual valve installed by your qualified service technician 6 Turn the manual valve clockwise to the OFF position 7 Wait five 5 minutes to c...

Страница 41: ...for 7 consecutive days once the pilot has been ignited If you have your Proflame 2 system set to CPI continuous pilot ignition with 7 consecutive days without ignition of the main burner the pilot wi...

Страница 42: ...ion above on this page 2 Set thermostat to lowest setting if applicable 3 Turn off all electric power to the appliance 4 Open the control compartment access panel 5 Push in gas control knob slightly a...

Страница 43: ...model SP 34 MV is fitted with a millivolt Pilot on Demand gas control valve equipped with a timer set for 7 consecutive days once the pilot has been ignited If there is no appliance operation within...

Страница 44: ...pressure settings 6 Set IPI CPI rocker switch to IPI OFF Press the main ON OFF rocker switch to OFF Pilot and burner should turn off 7 Disconnect hose and tighten the inlet IN pressure tap by turning...

Страница 45: ...switch to OFF 7 Turn the gas control knob to OFF 8 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 9 Relight pilot and turn t...

Страница 46: ...tioning before adjusting the venturi Logs must not block burner ports 1 Open control compartment access panel 1 Remove the safety barrier and glass frame assembly 2 Remove the log set and lava rock 3...

Страница 47: ...t the baffle out of slots on the firebox back wall 4 Bend the tabs on the restrictor plate included in fireplace components packet to approximately 80 angles This will create tension when the restrict...

Страница 48: ...tween the appliance and main gas line Pilot will not stay lit No propane in tank Check propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations...

Страница 49: ...t restriction after installation on page 47 Soot appears on glass Improper log placement Refer to Section 8 2 SP34 50A Log Set Installation on page 34 Improper venturi setting Venturi air shutter may...

Страница 50: ...connection at gas valve is full inserted and tight hand tight plus 1 4 turn Thermocouple reading below 15 millivolts Disconnect the thermocouple from valve Place one millivolt meter lead wire on the...

Страница 51: ...nd burner extinguish while in operation No propane in tank Check propane tank Refill if necessary Incorrect glass frame assembly installation Refer to Section 8 1 Glass Frame Assembly on page 54 Impro...

Страница 52: ...on Refer to Section 7 0 Venting on page 24 Performed by Qualified Service Person Frequency Annually Action Examination of the vent system is required The flow of combustion and ventilation air must no...

Страница 53: ...ice Visually check pilot light when in operation Continuous Pilot Ignition System Millivolt Ensure pilot flame impinges on thermocouple Clean pilot hold and adjust pilot flame at gas valve for proper...

Страница 54: ...c P O Box 577 204 Industrial Park Drive Lakefield MN 56150 0577 USA SP 34 MV and SP 34 LE SP 34 LE CONTROL BOARD AND PARTS Control Board Natural Gas SP34 140A Pilot Assembly Propane 700 551 1 Control...

Страница 55: ...SP34 4A Log SP34 4A SP34 5A Log SP34 5A SP34 6A Log SP34 6A 1 2 Lava Rock 600 702 Rock Wool Embers 900 REMB GLASS AND GLASS GASKET 28 x 20 1 2 Glass with Gasket 701 016T 1 1 8 Glass Gasket 900 006 Val...

Страница 56: ......

Страница 57: ...of but not limited to improper chimney venting installation will also render this warranty void 7 This warranty does not cover installation and operational related problems such as environmental cond...

Страница 58: ......

Отзывы: