#SP-34 LE & MV R.5 January 2020
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
ELECTRICAL INFORMATION 39
9.3 #SP-028 Optional Fan Kit
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
WARNING: Installation of this fan kit should be done by a qualified
installer. Verify household breaker is shut off prior to working on any
electrical lines.
NOTE: It easier to install the fan kit before connecting the gas line to
the control board.
•
This appliance, when installed, must be electrically grounded
in accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.
•
Code-approved line voltage wiring, 14 gauge or better, must be
used when wiring this assembly. Refer to your local electrical
codes for specific requirements.
•
A pre-installed electrical box is included with the appliance,
along with a receptacle/box cover assembly in the fireplace
components packet.
•
If installing this optional fan kit after appliance installation,
remove the control board to access the control compartment
and follow instructions below. Refer to 8.3 Control Board
Removal and Installation on page 35.
This kit includes:
(1) Fan assembly
(2) Philips head screws (black)
(1) Temperature control switch
with magnet attached
(1) Speed control box with
cord
1. Before unit installation, remove the back access panel (4) screws.
2. With the motor end facing to the right, slide the fan underneath
the firebox. The fan assembly has magnetic tape located on the
bottom and does not require mounting.
3. Mount the speed control box onto the lower right side frame.
Align the slots in the speed control box to the holes in bracket.
Secure with (2) black philips head screws (included).
4. Place the temperature control switch (magnet attached) onto
the firebox floor on the right.
5. Plug fan cord into the speed control assembly.
6. Plug the speed control box cord into the electrical box
receptacle.
7. Reinstall all components previously removed.
8. Turn speed control counter-clockwise until it ‘clicks’. This is the
OFF position.
Turn speed control ON by turning knob clockwise past the ‘click’ -
this is the highest setting.
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong plug on fan
cord from receptacle.
Adjust position of temperature control switch to a warmer location under
firebox to turn fan ON sooner or move it to a cooler location under firebox
to turn fan ON later. The fan will turn on when sensor in temperature
control switch reaches 110° F and will turn OFF when sensor reaches 90° F.
After adjustment, plug 3-prong plug on fan cord into receptacle.
TEMPERATURE CONTROL SWITCH
GROUND
GROUND
Figure 9.5, Access Panel Location
Figure 9.6, Speed Control Install
Figure 9.7, Fan Wiring