25
CONTROL BOARD REMOVAL / INSTALLATION
1. Use remote to turn fireplace off.
2. Remove glass frame assembly.
3. Shut off gas supply at manual shut-off valve.
4. Disconnect gas line flex tube from manual shut-off valve.
5. Unplug all components from receptacle, disconnect all wiring
harnesses attached to gas valve.
6. Remove glass media.
7. Remove burner cover (secured with (10) screws).
8. Remove burner tube from mounting cradles.
9. Remove (2) nuts securing light bar to control board, carefully
move light bar backwards far enough to clear board.
10. Remove (8) screws securing control board, lift board out of firebox being
careful not to damage sealing gasket lying underneath.
REMOVAL
INSTALLATION
1. Place control board in firebox, aligning holes in board to holes in
firebox bottom.
MAKE SURE SEALING GASKET IS IN PLACE ON
FIREBOX BOTTOM!
Secure with (8) screws previously removed.
2. Reinstall light bar onto control board, secure with (2) nuts
previously removed.
3. Reinstall burner, positioning burner venturi over burner orifice,
aligning burner tube with mounting cradles on control board.
4. Reinstall burner cover, aligning holes in cover to corresponding
holes in burner tube mounting cradles. Secure with screws (10).
5. Reinstall glass media, being careful not to block pilot.
6. Reconnect gas line to manual shutoff valve.
7. Reconnect all wiring harnesses to gas valve, Plug all components
into electrical outlet.
8. Reinstall glass frame assembly.
9. Turn gas on.
10. Verify proper glass media placement, operation of fireplace, and
any electrical components.
CAUTION
If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before
removing any components.
WARNING
DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER CONTROL BOARD) IN PLACE.
IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION
CHECK ALL CONNECTIONS FOR LEAKS WITH SOAPY WATER, WHETHER FIELD OR FACTORY MADE.
Figure 25a
Pilot
Burner orifice