#RVT-34-BW R.1 SEPT 2018
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
INSTALLATION
15
6.0 INSTALLATION
6.1 Approved Vent Systems
Kozy Heat #816 and #816-CAP
For use with minimum 6” x 8” I.D. masonry or 7” I.D. Class A metal
chimneys; includes one roll of 36’ (10.97 m) of expandable 3” flexible pipe
and round termination cap.
Other approved vent manufacturers
BDM, American Metals (Amerivent), Metal Fab, Olympia Venting Supply,
Selkirk, Simpson Dura-Vent, and ICC.
6.2 Kozy Heat #816 and #816-CAP
IMPORTANT: Proper operation of this insert requires the exhaust pipe
and combustion air pipe to be connected to their correct flue collar, on
both the termination kit and the gas fireplace insert vent adapter.
The fireplace insert exhaust flue collar is located on the right side.
Install termination cap with the exhaust flue collar on the right side.
NOTE: The exhaust pipe will have a red marking.
IMPORTANT: Maximum horizontal vent runs of 24 in (609 mm) require
a 1 in (25mm) rise per 12 in (305 mm) run. Care should be taken when
installing the flexible vent pipes to avoid a tight bend that may cause
abrasion or damage to the flexible pipes.
1. Measure the total chimney length required and cut #816 (36’
[10.97m] of 3” flexible pipe) to the measured length.
2. Carefully extend the exhaust and combustion air intake pipes to
total chimney length required.
3. Slide the combustion air intake pipe (the end without a collar)
over termination cap collar (A). Secure to #816-CAP termination
cap (E) with (3) self-tapping screws (not provided).
4. Place a bead of sealant around the inner edge at the end of the
exhaust pipe (without collar / red marking) and slide onto the
corresponding labeled collar (B) on termination cap (E).
5. Secure the exhaust pipe to termination cap (E) with (3) self-
tapping screws (not provided). Apply additional sealant around
joint to ensure a proper seal.
6. Complete vent system installation by following the instructions
outlined in Sections 6.3 through 6.6.
COMBUSTION AIR
INTAKE 3” FLEX LINER
EXHAUST VENT
3” FLEX LINER
USES #816 36 ft (10.97m) EXPANDABLE 3” FLEXIBLE PIPE
C
A
B
D
C
#816 and #816-CAP
(A)
Intake Collar (extends
through bottom plate)
(B)
Exhaust Collar (extends
through middle divider
plate)
(C)
Sealant (not provided)
(D)
#816-CAP Termination Cap
VENT ADAPTER (TOP VIEW)
COMBUSTION AIR
INTAKE COLLAR (LEFT)
EXHAUST COLLAR (RIGHT)
Figure 6.1, #816-CAP