#RVT-34-BW R.1 SEPT 2018
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
OPERATING INSTRUCTIONS
29
11.8 Remote Control Operation
11.8.1 Temperature Display
1. With the system in the OFF position, simultaneously press the
thermostat key and the mode key to change degrees from °F to
°C.
2. Visually check the LCD screen to verify either °F or °C is displayed
on the right side of the room temperature display.
11.8.2 Key Lock
This function locks the keys to avoid unsupervised operation. Once
activated, a lock icon will appear on the LCD screen.
1. Simultaneously press the mode key and the up arrow key to
activate or deactivate this function.
11.8.3 Pilot Ignition Selection (IPI/CPI)
This system has the option of a continuous (standing) pilot. This
features allows the system to change from a spark-to-pilot system
to the standing pilot option. The standing pilot will keep the firebox
warm and establish a draft in the vent, which allows the main burner
to ignite with less air-flow disruption.
When the system is OFF, the LCD screen will display the snowflake icon
during the setup of either IPI or CPI mode. To select the preferred pilot
ignition feature,
1. With the system in the OFF position, press the mode key to index
the CPI mode icon.
2. Press the up arrow key to activate CPI.
3. Press the down arrow key to return to IPI. A single ‘beep’ will
confirm reception of the command.
When the system is ON,
IPI mode:
LCD screen will not display the snowflake icon
CPI mode:
LCD screen will display the snowflake icon
PROFLAME 2 TRANSMITTER
LOW BATTERY ALARM
KEY LOCK
LIGHT ON
ROOM
TEMPERATURE
SET POINT
TEMPERATURE/LEVEL/STATE
FLAME ON
THERMOSTAT
OFF/ON/SMART
FAN
TRANSMISSION
SPLIT FLOW
CPI MODE
ON/OFF KEY
THERMOSTAT KEY
UP/DOWN ARROWS
MODE KEY
BLUE BACK
LCD DISPLAY
LCD DISPLAY