VENTING REQUIREMENTS:

THIS FIREPLACE IS APPROVED FOR USE WITH THE FOLLOWING 5" X 8" DIRECT VENT SYSTEMS:  SIMPSON DURA-VENT DV-GS,

AMERI-VENT, AND SELKIRK METALBESTOS.

THIS FIREPLACE IS ALSO APPROVED FOR USE WITH THE KOZY HEAT #800 SERIES FLEXIBLE VENT SYSTEM FOR HORIZONTAL

VENTING APPLICATIONS. 

THIS FIREPLACE IS DESIGNED TO BE USED WITH ANY OF THE ABOVE VENT SYSTEMS WITHOUT THE USE OF AN ADDITIONAL

ADAPTOR.

Contact your dealer for the appropriate venting components for your specific application.

VENT SYSTEM CLEARANCES:

Dura-Vent, Ameri-Vent, or Selkirk Metalbestos chimney systems:

Horizontal Sections: All Sides: 3"
Vertical Sections: All sides: 1"

#800 Series Flex Vent System: All sides: 3" 

IMPORTANT: 

THE KOZY HEAT WALL THIMBLE PASS-THRU, PART #MTK-WPT  MUST BE USED ON
ALL HORIZONTAL VENT RUNS.  THE MINIMUM WALL THICKNESS FOR THIS PASS-
THRU IS 4 ½" AND THE MAXIMUM WALL THICKNESS IS  8"

.

TYPICAL INSTALLATION OPTIONS:

Typical Horizontal Installation - Figure 3A

   

Typical Vertical  Installation - Figure 3B

   Typical Corner
Installation - Figure 3C

Clearance to Combustible Material
          diagram - Figure 3D

Refer to the vent system manufacturer’s installation manual for complete installation instructions.  Installation must conform with the venting
requirements & restrictions as outlined in this manual.

IMPORTANT:  

Consult the local and national installation codes to ensure that adequate combustion and ventilation air is available.

Содержание PRC-36

Страница 1: ...supplier from a neighbor s phone Follow your gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation service must be performed by a qualified installer...

Страница 2: ...BLE TERMINATION KIT INSTALALTION 14 15 FAN INSTALLATION 16 18 MODEL PRC 36 16 17 MODEL PRC 36 RF 18 GAS LINE SPECIFICATIONS 19 20 SECURE THE MILLIVOLT BOARD 20 ADJUST COMBUSTION AIR INTAKE SHIELD VERT...

Страница 3: ...BE APPLIED OVER THE FACE TO PREVENT THE FACING MATERIAL FROM CRACKING AND FALLING OFF DUE TO EXPANSION OF THE FACE WHEN HEATED DO NOT ATTACH FACING MATERIAL DIRECTLY TO THE FACE OF THE UNIT DO NOT OBS...

Страница 4: ...Page 4 SPECIFICATIONS Height 32 Height to top of stand off 42 Front width 35 7 8 Back width 24 5 8 Depth 21 3 8 Refer to Diagrams for additional measurements FIGURE 1...

Страница 5: ...wide X 21 3 8 deep HEARTH EXTENSIONS A HEARTH EXTENSION IS REQUIRED AND MUST COMPLY WITH THE FOLLOWING REQUIREMENTS RAISED HEARTH EXTENSION COMBUSTIBLE MATERIAL The minimum maximum hearth extension wh...

Страница 6: ...Vertical Sections All sides 1 800 Series Flex Vent System All sides 3 IMPORTANT THE KOZY HEAT WALL THIMBLE PASS THRU PART MTK WPT MUST BE USED ON ALL HORIZONTAL VENT RUNS THE MINIMUM WALL THICKNESS FO...

Страница 7: ...45 degree elbow then maximum horizontal 10 ft VERTICAL TERMINATIONS Minimum 45 degree elbow at start followed by 2 ft Maximum 45 degree elbow at start followed by a maximum 30 ft CORNER INSTALLATION...

Страница 8: ...to horizontally position the vent system Horizontal Vent NOTE Option 1 shown in Figure 4A Heat Shield A maximum horizontal run of 5 feet is allowed for this venting configuration Horizontal Terminatio...

Страница 9: ...ilated soffit 12 E 6 Outside inside corner 6 F 7 Meter Regulator NOT TO BE INSTALLED ABOVE within 3 ft horizontally from the center line of the regulator 8 Service regulator vent outlet 3 ft radius 9...

Страница 10: ...himney Height Flat to 6 12 1 ft 13 12 to 16 12 6 ft 6 12 to 9 12 2 ft 17 12 to 21 12 8 ft 10 12 to 12 12 4 ft CAUTION This gas appliance must not be connected to or joined with any chimney flue servin...

Страница 11: ...xible vent system for horizontal terminations Refer to page 12 of this manual for instruction on attaching the horizontal vent heat shield Frame a 14 1 8 high H x 14 1 8 wide W opening on the exterior...

Страница 12: ...ials Adjust rough opening size as necessary to maintain at least the minimum clearance requirements MINIMUM FINISHED OPENING DIMENSIONS Wall covering facing materials included HORIZONTAL TERMINATIONS...

Страница 13: ...ace 3 Removetheremaining 2 setsofscrewsunderthestand off brackets and set aside 4 Form each stand off as shown in Figure 8B Figure 8B 5 Re attach the stand off brackets to the top of the fireplace usi...

Страница 14: ...LASS ASSEMBLY See Figure 11 A Locate the spring loaded handles securing the glass assembly at the top bottom of the firebox CAUTION TO PREVENT THE GLASS ASSEMBLY FROM FALLING FROM THE FIREPLACE AND BE...

Страница 15: ...UST BE USED FOLLOW INSTRUCTIONS INCLUDED CAUTION This gas appliance must not be connected to a chimney flue serving another type of appliance 1 If your vent system application is 8 or less from the to...

Страница 16: ...n fit between these brackets and using the screws provided screw the brackets to the termination kit box A Attach the vinyl siding protector G 8 Apply a liberal bead of exterior sealant around the out...

Страница 17: ...control assembly and 3 wire nuts are included in the fireplace components packet This optional fan kit part TRF 028 includes Right left fan assemblies with thermostatic control switch Components packa...

Страница 18: ...receptacle assembly into the electrical box with the 2 screws provided 8 Replace the electrical access panel and secure with the 2 screws removed 9 Place the thermostatic control switch on the bottom...

Страница 19: ...grounding plug for protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Figure 15 1 Re...

Страница 20: ...lo setting 1 7 inches W C Orifices sizes 37 55 Input 35 000 BTU hr Efficiency 68 33 AFUE 67 69 P 4 AFE 54 77 Minimum input 22 500 BTU hr LP GAS The minimum inlet gas supply pressure 11 0 inches W C r...

Страница 21: ...oard burner log grate pilot shield cover assembly already installed 1 Referring to the INSTALLING THE MILLIVOLT BOARD section on pages 32 33 check to ensure that all 8 screws securing the millivolt bo...

Страница 22: ...ORT HOLES 2 Position base logs P2 P3 P4 M6 onto the burner as shown in Figure 17A Adjust log position so that they are close to the burner port holes but do not cover them Figure 17B P7 P5 P6 P9 P8 3...

Страница 23: ...ch wall switch thermostat wire and connect to the top and bottom terminals on the gas valve marked TH REMOTE CONTROL USERS Follow instructions included with the remote control IMPORTANT The insulated...

Страница 24: ...Y NON COMBUSTIBLE MATERIAL MUST BE USED FOR A MINIMUM OF 10 FROM THE TOP OF THE FACE AT THE FRONT OF THE FIREPLACE COLD AIR TRANSFER The surrounding wood chase of the outside wall must be insulated to...

Страница 25: ...of the upper hood into the clips located in the top of the upper air passage NOTE This is a fairly tight fit Figure 20B C Partially thread the 2 screws included in the components packet into the nuts...

Страница 26: ...air it call a qualified service technician Forced or attempted repair may result in a fire or explosion and loss of warranty 4 Do not use this appliance if any part has been under water Immediately ca...

Страница 27: ...switch or adjust the setting on the thermostat or remote control NOTE The pilot will stay lit TO TURN THE PILOT OFF To turn off the pilot push in and turn the control knob to the OFF position DO NOT...

Страница 28: ...d pressure reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure check TO CHECK THE INLET PRESSU...

Страница 29: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water DONOTSTOREORUSEGASOLINEOROTHERFLAMMAB...

Страница 30: ...the control knob clockwise to the pilot position REMOTE SETTING The RT8220A transmitter can shut off the main burner and fan However the control is still on and a command from the transmitter can turn...

Страница 31: ...he gas supply at the manual valve in the gas piping to the appliance or for LP at the tank 9 Loosen but donot remove the inlet tap captive screw 10 Attach a plastic tube with a 1 4 shell ID and connec...

Страница 32: ...Y SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSEIMPROPERA...

Страница 33: ...tacle then disconnect the 2 wires from the fan cord Note the wires will remain connected to the back of the gas valve Refer to wiring diagram Figure 15 page 18 of this installation manual 6 Remove the...

Страница 34: ...page 32 3 To install the burner log grate assembly the adjustable venturi must be set to the LP gas position This will provide easiest method of installation TO SET THE ADJUSTABLE VENTURI Loosen and...

Страница 35: ...le gas line to the manual shut off valve 11 Model PRC 36 Re connect any wall switch remote control or thermostat wires onto the top bottom terminals on the gas valve marked TH 12 Model PRC 36 RF Re co...

Страница 36: ...hen piezo Wire on back of piezo button is loose or off Put wire back into place button is depressed Wire from piezo to electrode is loose at electrode Reconnect wire Electrode moved out of position Re...

Страница 37: ...erator millivolts to operate burner Wall switch remote control or thermostat not Connect properly or disconnect connected properly or turned to wrong setting See and use ON OFFswitch only Figures 18A...

Страница 38: ...37 back burner 700 109 Honeywell RF Pilot Assembly 700 255 Natural Gas orifice 55 front burner 700 060 Flexible Pilot Tubing Valve to Pilot 700 252 LP Gas orifice 52 back burner 700 083 Piezo Ignitor...