Page 12
PREPARE THE FIREPLACE
STAND-OFF ASSEMBLY & INSTALLATION
1. The top stand-off brackets must be formed and correctly
positioned prior to positioning the fireplace into the framed
opening. Figure 8A.
The top stand-off brackets are attached to the top of the
fireplace in a flat state when the fireplace is shipped.
2. Remove the screws securing each stand-off bracket and
remove from the fireplace.
3. Remove the remaining (2) sets of screws under the stand-off
brackets and set aside.
4. Form each stand-off as shown in Figure 8B.
Figure 8B
5. Re-attach the stand-off brackets to the top of the fireplace
using the screws removed in steps 2 & 3 above. Figure 8C.
Figure 8A
Figure 8C
HORIZONTAL VENT APPLICATIONS:
ATTACH THE HORIZONTAL VENT HEAT SHIELD:
1. Loosen, but do not remove the center three screws at
the back of the fireplace as shown in Figure 9A.
Figure 9A
2. Slide the (3) slots on the horizontal vent heat shield under the
screws. Re-tighten the screws to secure in place. Refer to
Figure 9B.
Figure 9B