MODEL #PRC-36 ONLY: OPTIONAL FAN INSTALLATION INSTRUCTIONS
I
NSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
IMPORTANT: If a fan is going to be installed, it is easier to complete before the millivolt board is connected to the gas line.
The wiring must be done prior to enclosing the sides of the unit. An electrical box & romex connector are pre-installed
on a removable panel on the right side of the fireplace. A receptacle / speed control assembly and (3) wire nuts are
included in the fireplace components packet.
This optional fan kit, part #TRF-028, includes:
Right & left fan assemblies with thermostatic control switch
Components package: Installation instructions
NOTE:
Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer to your local
electrical codes for specific requirements in your area.
WARNING: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.