GAS LINE CONNECTION 

PAGE 11 

Run gas line through left gas line access hole at back corners of insert. For your convenience, access hole may be removed and rotated to 
accommodate side gas line installation.  

NOTE: If installing this gas fireplace insert into a factory-built fireplace and the factory-built fireplace has no access hole provided, an    

access hole of 1-1/2"(38mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like 
manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed. 

This fireplace is manufactured for use with Natural Gas. An LP conversion kit is included with this fireplace.  
Follow instructions included with conversion kit if converting to LP gas. 

GAS CONVERSION

 

CAUTION:  Installation of the gas line must only be done by a qualified person in accordance with local building codes, if any.  
                      If not, follow ANSI 223.1.   
    
                      Commonwealth of Massachusetts: Installation must be done by a licensed plumber or gas fitter. 

IMPORTANT: 

 

The efficiency rating of this appliance is a product of thermal efficiency rating determined under continuous operating  

 

          conditions and was determined independently of any installed system.

 

ATTENTION: The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and 
 

         in accordance with the requirements of the ANSI Z223.1 installation code. 

NOTE:  A listed (and Commonwealth of Massachusetts approved) 12” (13mm) manual shut-off valve and flexible gas connector 

(included) are connected to the 1/2” (13mm) control valve inlet. If substituting for these components, please consult local 
codes for compliance. 

 

NOTE: This fireplace is equipped with a 3/8” (10mm) x 18” (457mm) long flexible gas connector and manual shut-off valve. The gas 

line should be run to the point of connection where the shut-off valve and flexible gas line will connect. 

 

NOTE: The appliance and its individual shutoff valve must be disconnected from  gas supply piping system during any pressure 

testing of that system at pressures in excess of ½ psi. 

 

NOTE: The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any  

 

 pressure testing of the gas line at test pressures equal to or less than ½ psi (3.5 kPa). 

 

NOTE: For high altitude installations, consult  local gas distributor or authority having jurisdiction for proper rating methods

.

 

 

MPS-34 

NATURAL GAS 

LP GAS 

MINIMUM INLET GAS PRESSURE 

5.0 inches W.C.  (7.0 W.C. recommended) 

11.0 inches W.C. (recommended) 

MAXIMUM INLET GAS PRESSURE  10.5 inches W.C. 

13.0 inches W.C. 

MANIFOLD PRESSURE (HI) 

3.5 

10 

MANIFOLD PRESSURE (LO) 

0.7 

2.8 

ORIFICE SIZES 

#41 

#53  

INPUT BTU/hr. 

25,000 

25,000 

MINIMUM INPUT BTU/hr. 

13,000 

13,000 

The manual shut-off valve is located on left side wall of insert. Use glass 
latch attachment tool (included in components packet) to open or close 
valve.  

MANUAL SHUT-OFF VALVE 

 

SHOWN IN OPEN POSITION 

Figure 11a  

Содержание MPS-34 Minneapolis XL

Страница 1: ...Vehicles and Mobile Housing CSA Z240 4 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance IF YOU SMELL GAS Do not light any appliance Do...

Страница 2: ...on and reliability but customer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong Dudley Hu...

Страница 3: ...Conversion Kit Instructions 12 13 GLASS FRAME ASSEMBLY SCREEN FRONT Glass Frame Assembly Screen Front Removal Installation 14 INSTALLATION Approved Venting 14 Combustion Air Venting Options 14 Air Du...

Страница 4: ...keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Clothing or other flammable material should not be place on or near the appliance Adequate access...

Страница 5: ...Black firebox liner Glass Media Kit IPI control system with remote control Engineer designed burner system Automatic fan kit 1 75 CFM Light Kit Co linear vent system 3 combustion air 3 exhaust Innovat...

Страница 6: ...8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print no less the one half inch 1 2 in...

Страница 7: ...t Center FIREPLACE DIMENSIONS INCHES 23 5 8 34 28 3 16 16 3 8 24 1 2 7 1 4 1 3 8 10 1 4 6 1 8 MILLIMETERS 600 864 716 416 622 184 35 260 156 1 Fireplace insert 2 Air chute 3 Module panel assembly 4 Va...

Страница 8: ...SPECIFICATIONS PAGE 7 MINIMUM CLEARANCES TO COMBUSTIBLES Figure 7a...

Страница 9: ...Glass Media Kit 2 JXL 057T Glass Frame Assembly OCK A53L I MXL PSE LP Conversion Kit 816 CL1 Co Linear Air Duct 700 208 Remote Control 700 GLT Glass Latch Tool Vent System Part 816 CL For use with min...

Страница 10: ...nside diameter Existing Chimney Height Minimum 10ft 3 05m Maximum 35ft 10 67m 1 Remove and discard existing chimney cap 2 Position one person at fireplace and another person at top of chimney Measure...

Страница 11: ...s screen rails screen mesh and log grates may be removed from existing fireplace before installing this gas fireplace insert Any smoke shelves shields and baffles may be removed if attached by mechani...

Страница 12: ...ith the requirements of the ANSI Z223 1 installation code NOTE A listed and Commonwealth of Massachusetts approved 12 13mm manual shut off valve and flexible gas connector included are connected to th...

Страница 13: ...so now before installing into existing fireplace REPLACE BURNER ORIFICE 1 Remove burner secured with 2 screws 2 Remove existing orifice cap Replace with orifice cap included with kit making sure to ti...

Страница 14: ...pressure Visually check pilot flame Flame should envelope top of flame sensor and extend onto burner far enough for prop er ignition To Adjust pilot Turn pilot adjustment screw clockwise to decrease...

Страница 15: ...ith slots on insert set into position To remove Lift frame up and out of slots PAGE 14 Figure 14a INSTALLATION COMBUSTION AIR VENTING OPTIONS OPTION 1 FULL CONNECTION Combustion air intake pipe is run...

Страница 16: ...sealant around inner edge at end of exhaust pipe without collar red marking and slide onto corresponding collar on termination cap collar with label Secure with 3 self tapping screws provided Apply ad...

Страница 17: ...sen vent system OPTIONAL 816 CL kits Secure termination cap to existing chimney with 2 self tapping screws and anchor straps provided through pilot holes located at sides of termination cap 3 From ins...

Страница 18: ...llar on air duct Slide combustion intake pipe over collar Secure with 3 self tapping screws provided To ensure an air tight seal apply additional sealant around joint 4 Slide insert into fireplace ope...

Страница 19: ...ION Disconnect all electrical power from fireplace before performing this task NOTE To avoid damage and prolong the life of halogen bulbs never touch with bare hands Always use a soft cloth when handl...

Страница 20: ...19a IMPORTANT THIS SYSTEM REQUIRES ELECTRICITY 110 V AND OR BATTERIES TO OPERATE USING BATTERY BACK UP WILL OPERATE BURNER ONLY FAN COMPONENTS WILL NOT FUNCTION ON BATTERY BACK UP POWER Light kit not...

Страница 21: ...OR LOW LIMIT SCREW STEP MOTOR WIRE HARNESS MAIN VALVE INTERNAL SOLENOID CONNECTION PILOT INTERNAL SOLENOID CONNECTION PILOT ADJUSTMENT SCREW INLET PRESSURE SCREW OUTLET MANIFOLD PRESSURE SCREW IPI GAS...

Страница 22: ...N OFF SWITCH LEARN BUTTON MAIN CONTROL MODULE VALVE STEP MOTOR TERMINAL COMMUNICATION LINK TO EXTENSION MODULE AC ADAPTOR CONNECTION EXTENSION MODULE COMMUNICATION LINK TO CONTROL MODULE POWER TO LIGH...

Страница 23: ...CONTROL INFORMATION CHILD PROOF ICON LIGHT LEVEL FLAME HEIGHT FAN SPEED BATTERY LIFE ICON THERMOSTAT MODE ICON SET TEMPERATURE visible only in THERMO MODE MANUAL ON OFF ROOM TEMPERATURE CONTINUOUS PI...

Страница 24: ...d may cause an explosion Disconnect 110V before servicing The IPI gas control system has the option of a continuous standing pilot feature This allows you to change from a spark to pilot system to a s...

Страница 25: ...n on right side access panel A Velcro strip has been attached to help secure in place The Hand Held Remote operates on 2 1 5V AAA batteries We recommend always using ALKALINE batteries to extend batte...

Страница 26: ...ain will turn fireplace OFF NOTE The MODE button operates in a series that will cycle from ON to THERMO to OFF FAN MODE This remote will operate the fan allowing for 6 different speed levels When the...

Страница 27: ...ature The FLAME ON and THERMO icons will appear on the LCD screen By pressing UP or DOWN buttons a new set temperature may be attained SET Temperature will only appear when THERMOSTAT MODE is activate...

Страница 28: ...P CHILDREN CLOTHING AND FURNITURE AWAY This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air WHAT TO DO IF YOU SME...

Страница 29: ...not operate follow instructions TURNING OFF GAS TO FIREPLACE and call your service technician or the gas supplier ATTENTION This fireplace is equipped with an ignition device which automatically light...

Страница 30: ...re Follow instructions below for proper testing procedures INLET PRESSURE TEST PRESSURE TESTING NOTE If inlet pressure reading is too high or too low contact the gas company Only a qualified gas servi...

Страница 31: ...ot flame is actually present when valve is turned OFF if yes replace valve Replace pilot assembly Replace module SENSOR SAFETY Protection for Flame Sensor Error Code Four beeps every two seconds Descr...

Страница 32: ...YOUR INSTALLATION NATURAL GAS LP PROPANE GAS 1 16 2 mm OPEN 5 8 16mm OPEN BURNER TUBE VENTURI ADJUSTMENT GUIDELINES VENTURI POSITION FLAME COLOR VENTURI ADJUSTMENT Closed too far Dark orange flame wit...

Страница 33: ...d agency is required IF VENT AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON RE INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL INSTALLATION The flow of combustion and ventilation air must not be obst...

Страница 34: ...ing for a beep from receiver when ON is pressed on hand held remote If you do not hear a beep ensure main control module has learned the hand held remote See above Ensure black lead from pilot assembl...

Страница 35: ...may take up to 3 hours for the temperature inside a packaged transmitter and several minutes for an unpackaged transmitter to equalize with room temperature FIREPLACE WILL NOT RESPOND IN THERMO MODE...

Страница 36: ...Natural Gas Orifice 41 700 404 MXL 1 Minneapolis XL IPI Valve LP 700 253 LP Gas Orifice 53 700 200 Pilot Assembly Natural Gas OCK A41N I MXL PSE Natural Gas Conversion Kit 700 200 1 Pilot Assembly LP...

Страница 37: ...PAGE 36 LIMITED WARRANTY...

Страница 38: ...PAGE 37 LIFETIME WARRANTY...

Отзывы: