background image

Содержание JOR-30S

Страница 1: ...injury death or property damage This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is o...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...CONNECTION 18 7 1 Gas Conversion sold separately 18 7 2 Gas Line Installation 18 8 0 FACING AND FINISHING 19 8 1 Clearances to Combustibles 19 8 2 Shroud Installation 20 8 3 Safety Barrier Installatio...

Страница 6: ......

Страница 7: ...s shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimu...

Страница 8: ...D3333 1313 2 2 Heating Specifications Natural Gas LP Gas Maximum Input Rating 30 500 Btu h 8 9 kW 30 500 Btu h 8 9 kW Minimum Input Rating 12 000 Btu h 3 5 kW 11 000 Btu h 3 2 kW Manifold Pressure Hig...

Страница 9: ...767 Opening Width D 26 1 4 666 Back Width E 24 3 8 619 Depth F 15 5 8 397 Height to Air Duct Top G 21 1 8 537 Unit Bottom to Gas Line Access H 14 1 8 360 Back to Gas Line Access I 1 1 4 32 Unit Bottom...

Страница 10: ...e to use only specified approved parts with this appliance may result in property damage or personal injury Table 2 2 Field Assembled Parts A Fireplace insert F Back burner assembly B Module panel ass...

Страница 11: ...ced with Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used Please refer to Section 8 3 Safety Barrier Installation on page 20 for installation instruction...

Страница 12: ...16 in 406 mm D Back Width 245 16 in 618 mm If installing the JOR FLP add 1 in 25 mm total dimension of floor protector and airspace to height to maintain minimum existing fireplace height opening requ...

Страница 13: ...appliance must not share or be connected to a chimney flue serving a separate solid fuel burning appliance Approved vent caps require 12 in 305mm clearance to intersecting walls overhangs or eaves as...

Страница 14: ...to Section 7 0 Gas Line Connection on page 18 If the factory built fireplace has no gas access hole s provided an access hole of 1 in 37 5 mm or less may be drilled through the lower sides or bottom...

Страница 15: ...pipe will have a red marking IMPORTANT Maximum horizontal vent runs of 24 in 609 mm require a 1 in 25mm rise per 12 in 305 mm run Care should be taken when installing the flexible vent pipes to avoid...

Страница 16: ...mination cap into position as instructed by vent system manufacturer s installation manual OPTIONAL Kozy Heat 816 CL Secure termination cap to existing chimney with 2 in 50 mm self tapping screws and...

Страница 17: ...e an air tight seal AIR DUCT Figure 6 4 Air Duct in Existing Fireplace FLEXIBLE PIPES SHEET METAL SCREWS 3 TOTAL SEALANT SEALANT 6 5 Place and Secure Appliance 1 Slide the gas fireplace insert into ex...

Страница 18: ...be isolated from the gas supply piping system by closing its individual manual shut off valve A listed and Commonwealth of Massachusetts approved in 13 mm tee handle manual shut off valve and flexible...

Страница 19: ...servicing and proper operation must be maintained COMBUSTIBLE MATERIAL 3 76mm CLEARANCE TO ADJACENT SIDEWALL Hearth Protection X Clearance to Combustible Floor Y 0 in 0 mm 5 in 127 mm 4 in 102 mm 2 1...

Страница 20: ...orresponding mounting nuts in mounting brackets on each side of the insert metal cabinet 3 Secure with 4 phillips truss head screws provided 4 Reinstall glass frame assembly 8 3 Safety Barrier Install...

Страница 21: ...hile lowering the bottom of the glass assembly into position 2 Using the glass latch tool pull latches out and down over latch tabs to secure glass frame assembly bottom Figure 9 1 Lower Latch 1 each...

Страница 22: ...ustrations for proper log placement 1 Place the ember panels behind the front burner ports as shown below 2 Align the holes in the bottom of logs J30 1 and J30 2 with the mounting pins on the back bur...

Страница 23: ...side 7 Remove front burner assembly by lifting it up and off the front burner orifice 8 Remove 10 screws securing the control board on the left side of the firebox 9 Pull out control board out to rev...

Страница 24: ...remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes wi...

Страница 25: ...appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit conde...

Страница 26: ...ialized 6 Slide the control module access switch to ON position for remote control operation of the main burner and fireplace features Figure 11 1 Battery Holder Box and Battery Holder Clips 11 3 Rese...

Страница 27: ...oximately 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After ap...

Страница 28: ...ng pilot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD scre...

Страница 29: ...can be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature...

Страница 30: ...time for heat to build in fireplace before fan operation The fan will continue to operate for approximately 12 minutes after the fireplace has been turned off Manual mode Fan s will operate at previo...

Страница 31: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Страница 32: ...Venturi Opening Adjustment NOTE If soot is present on the glass check log positioning before adjusting the venturi Logs must not block burner ports IMPORTANT Slight adjustments to the venturi opening...

Страница 33: ...o LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a...

Страница 34: ...mix Refer to Section 12 2 1 Burner Venturi on page 32 Incorrect vent cap installation Adjust if necessary Vent cap blockage Remove debris if necessary Flame burns blue and lifts off burner Improper ve...

Страница 35: ...System NOTE If the vent air intake system is disassembled for any reason reinstall per instructions provided with installation Section 6 0 Installation on page 15 Performed by Qualified Service Perso...

Страница 36: ...0 S 540 Split Flow 700 595 Conversion Kit LPG LCK J30 S Transmitter Remote Control with Split flow 700 508 Front Burner J30 350 Pilot Orifice NG 62 700 166 Back Burner J30 351 Pilot Orifice LPG 35 700...

Страница 37: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Страница 38: ......

Страница 39: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Отзывы: