11.1 Setup Proflame 2 IFC Module
1. Locate the battery holder box / control module access switch
on the left side of the fireplace.
2. Set the control module access switch to OFF position.
3. Locate the battery holder clips (Figure 11.1). Depress the
clips to open the battery cover and install (4) AA batteries
(included in the components packet). The correct polarity is
marked on the battery cover.
4. Install (3) AAA batteries (included in the components packet)
in the remote control battery bay, located at the base of the
remote.
5. Connect the IFC Module to an AC power supply.
11.2 Initialize the Control System
IMPORTANT: Remove all packaging and combustible material
from the firebox before initializing the control system.
NOTE: Performing the next steps will initiate pilot start-up in
manual mode, where the pilot igniter will spark repeatedly. The
pilot will ignite if gas is supplied to the fireplace.
1. Locate the battery holder box / control module access switch
on the left side of the fireplace.
2. Slide the control module access switch to ‘REM’ position.
3. Press the ‘PRG’ button (see Figure 11.2). The IFC module will
BEEP (3) times, indicating the receiver is ready to synchronize
with the transmitter.
4. Within (5) seconds, push the ON/OFF button on the
remote control. The receiver will BEEP (4) times to indicate
the transmitter’s command is accepted, and is set to the
transmitter’s particular code. The pilot will automatically ignite.
5. Press the remote control ON/OFF button again. The pilot
will extinguish, confirming the remote control command. The
control system is now initialized.
6. Slide the control module access switch to ON position for
remote control operation of the main burner and fireplace
features.
Figure 11.1, Battery Holder Box and Battery Holder Clips
11.3 Reset the System for
Manual Operation
1. Set the control module access switch to OFF position.
2. Press the ‘PRG’ button on the battery box holder until it emits
(3) beeps and an amber LED is illuminated.
3. Within (5) seconds, press the ‘PRG’ button again. This will
close synchronization with the remote control. The pilot will
automatically light.
• Turn the main burner ON by setting the control module access
switch in ON position. The main burner will only operate on HI.
• Turn the main burner OFF by setting the control module
access switch in the OFF position. The pilot will remain lit even
if burner is turned off, provided CPI mode is turned on.
11.4 Automatic Safety Restart
• This system will execute an automatic turn OFF command
within (24) hours of a continued pilot flame ignition. This allows
the system to verify correct safety functions.
• After the turn OFF sequence is completed, the IFC module will
re-execute the latest command.
11.5 Backup Battery Operation
This appliance will operate on the backup battery pack when
electric power is interrupted, or in a power outage. The lifespan of
the backup batteries depend on various factors, such as the quality
of the batteries, number of ignitions, et cetera.
• When the backup battery pack is low, the IFC module will emit
a double-beep while receiving an ON/OFF command.
• No commands will be accepted after this alert until the back
up batteries are replaced.
• Once replaced, the IFC module will emit a ‘beep’ as soon as
it is powered.
Figure 11.2, Control Module Access Switch and ‘PRG’ Button