9
5.0
INSTALLATION PREPARATION
5.1
Inspect and Clean Existing Chimney
ATTENTION
Any removed parts must be capable of reinstallation if this insert is ever removed. Removal of rivets or screws is acceptable.
NOTE
This gas fireplace insert is approved for installation in masonry and factory-built solid fuel burning fireplaces.
Verify existing chimney is constructed of non-combustible material.
Verify existing chimney is clean and in good working order. Clean existing chimney and fireplace to prevent a creosote odor
from entering the home.
Verify combustible mantel and sidewall clearances comply with Section 6.0, Clearances, on page 10.
Any smoke shelves, shields, and baffles may be removed if attached by mechanical fasteners.
The refractory, glass doors, screen rails, screen mesh, and log grates may be removed from existing fireplace before installing
this gas fireplace insert.
5.2
Flue Damper
The fireplace flue damper can be fully blocked open, or removed for installation of this gas fireplace insert. Remove existing
chimney cap.
5.3
Gas Line
A gas line must be able to be installed to the insert. Refer to Section 8.0, Gas Line Connection, on page 15.
If the factory-built has no gas access hole(s) provided, an access hole 1-1/2 in (37.5mm) or less may be drilled through the
lower sides or bottom of the firebox in a proper workmanship like manner. The access hole must be plugged with non-
combustible insulation after the gas supply line has been installed.
Run gas line to the gas fireplace insert through the gas line hole provided. Do not run gas line in a manner that would obstruct
fan operation.
If the gas fireplace insert is to be installed into minimum opening dimensions, the gas line may need to be run after appliance
placement due to space limitations.
5.4
Electrical Wiring
Provisions must be made to provide electrical power for appliance operation.
Refer to Section 2.4 Appliance Dimensions on page 5 for electrical outlet box location to run any necessary electrical wiring to
the gas fireplace insert.
5.5
Fireplace Conversion
Mechanically attach the label with the following warning at the bottom existing firebox so it will be visible if this gas fireplace
insert is removed.
WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning
wood or solid-fuels unless all original parts have been replaced, and the fireplace re-approved by the Authority Having
Jurisdiction.