16
9.3
#CSK-028 Optional Fan Kit
NOTE: It easier to install the fan kit before connecting the
gas line to the control board.
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the absence
of local codes, with the National Electrical Code, ANSI/
NFPA 70, or the Canadian Electrical Code, CSA C22.1.
Code-approved line voltage wiring, 14 gauge or better, must
be used when wiring this assembly. Refer to your local
electrical codes for specific requirements.
A pre-installed electrical box is included with the appliance,
along with a receptacle/box cover assembly in the fireplace
components packet.
Kit Components: (2) 75 CFM fan with temperature control switch
(4) 1/4” nuts
1. Remove safety barrier and glass assembly.
2. Slide the left fan through the lower grill opening and position
onto corresponding mounting studs on the floor of the unit.
Secure with (2) nuts included. Repeat with right fan.
3. Place temperature control switch on the bottom of firebox.
4. Plug fan cord into receptacle in the electrical box.
5. Turn speed control counter-clockwise until it ‘clicks.’ This is
the OFF position. Turn speed control ON by turning knob
clockwise past the ‘click’ - this is the highest setting.
6. Reinstall all components previously removed.
IMPORTANT: This fan will not operate unless speed control
has been turned ON and sufficient heat has been applied to
temperature control switch. The fan will turn ON and OFF
automatically as fireplace heats and cools. Adjust fan to
desired speed while it is running.
WARNING
Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug.
Installation of this fan kit should be done by a qualified installer. Verify household breaker is shut off prior to working on any electrical
lines.
Figure 9.4, Fan Wiring
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting temperature control switch, unplug 3-prong
plug on fan cord from receptacle.
Adjust position of temperature control switch to a warmer
location under firebox to turn fan ON sooner or move it to a
cooler location under firebox to turn fan ON later. The fan
will turn on when sensor in temperature control switch
reaches 110° F and will turn OFF when sensor reaches 90° F.
After adjustment, plug 3-prong plug on fan cord into
receptacle.