Facing and Finishing Requirements
SECTION 4
FACING AND FINISHING
#CAR-39
R.11 February 2022
24
HUSSONG MFG. CO., INC.
KOZY HEAT FIREPLACES
64
½
”
(1638mm)
34
½
”
(876mm)
6”
(152mm)
12”
(305mm)
12” (305mm)
9” (229mm)
6” (152mm)
Non-combustible Zone
Non-combustible
material only
Insulation piece MUST rest
against non-combustible material
Combustible floor
Non-combustible
material only
FIGURE 4.2
Non-Combustible Mantel Requirements
Nominal 2“ x 4” framing used in enclosure framing