3.8 Vented Cavity
3.8.1 Single Opening Vented Cavity Option
WARNING: Enclosure measurements must maintain minimum framing
specs as outlined in Section 3.7.2.4 Rough-in Wall Enclosure on page
23. Minimum dimensions for the air discharge MUST BE maintained
after all finishing materials are installed.
NOTE: The single opening vented cavity option allows the use of 19
gauge (or less) 1/2” x 1/2” hardware mesh to prevent any items from
entering the vented cavity. This hardware mesh is optional and the
ONLY approved item for use within the air discharge opening.
WARNING: Do NOT cover or place any items in the air discharge
opening area. Grilles and louvers are NOT allowed.
WARNING: Failure to comply with these instructions could create
a fire hazard. Ensure air flow within the air discharge opening is not
restricted in any way
These are minimum dimensions shown for the air discharge
opening, and the opening may be increased, if desired, as long
as all requirements are followed. It is recommended to limit your
opening size for aesthetic purposes and to avoid items falling into the
enclosure.
•
Figure 3.15 shows the minimum required dimensions for the
vent cavity air discharge opening.
•
This singl
e 3” (height) x 43” (width)
air discharge opening can be
located at the front of the fireplace chamber, or located at the
rear of the fireplace chamber (to an adjacent room).
•
Hot air will exit to the room where the air discharge opening is
located.
Single opening cavity option with air discharge in front
Single opening vented cavity with air discharge located in rear (to adjacent room)
3”
(76mm)
43”
(1092mm)
3”
(76mm)
43”
(1092mm)
Figure 3.15, Single Opening Vented Cavity Installation
SINGLE OPENING VENTED CAVITY INSTALLATION
24
FRAMING
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#CLW-40 R.3 November 2021