3.7.2.4 Rough-in Wall Enclosure
WARNING: Provide adequate clearance in front of the fireplace for
barrier removal, component access, gas line installation, service
access, etc.
CAUTION: Cold air transfer area. The surround fireplace chase
must comply with all clearances as outlined in this manual, and be
constructed in compliance with local building codes. Outside walls
should be insulated to prevent cold air from entering room.
•
Minimum rough framing dimensions for KZK-044, KZK-158A, and
vented cavity installation are shown below in Figure 3.14.
•
Floor protection in front of the fireplace is not required.
Combustible material may be used if installing a hearth
extension. Consider the thickness of the hearth extension
finishing material if building a fireplace platform.
If using a safety
screen only, the hearth may be flush with the finishing edge. If
using a surround, the bottom of the fireplace surround must be
level with finished hearth extension for proper fit of the optional
surround.
•
The bottom of the fireplace must be placed directly on a wood
or non-combustible surface (not linoleum or carpet). If this
appliance is to be installed directly on carpeting, tile, or other
combustible material other than wood flooring, this appliance
shall be installed on a metal or wood panel extending the full
width and depth of the appliance.
•
This fireplace may be elevated off the floor, provided it is
properly supported by framing materials and maintains ceiling
clearances. If installed above floor level, a solid, continuous
platform must be constructed below the fireplace.
•
If masonry (optional) is to be used, prepare the foundation
necessary for the full masonry load.
3.7.2.5 TV Recess Construction
WARNING: All clearances to venting must be maintained.
Mounting a television above a fireplace is a common practice. Mantel
depth, ceiling heights, and wall and mantel construction material all
affect television surface temperatures. Most television manufacturers
specify in their instructions that a television should not be installed
on, near, or above a heat source.
Tests performed determined that surface temperatures did not exceed
150°F (66°C) when a 4-1/4” (108mm) deep recess is constructed above
the fireplace when installed with the KZK kit(s) or Vented Cavity
option. It is the homeowner’s responsibility that the preferred TV
mounting and mantel design will not exceed the listed maximum
operation temperature of their electronic goods.
74”
(1880mm)
47
½
”
(1208mm)
47
¼
”
(1200mm)
4
¼
”
(108mm)
56
½
”
(1435mm)
74”
(1880mm)
22”
(559mm)
47
¼
”
(1200mm)
Ceiling/Fireplace enclosure top
Finishing Edge
TV Recess
Ceiling/Fireplace
enclosure top
Standoff Assembly
(See section
3.7.1
)
Double horizontal
header
Figure 3.14, KZK and Vented Cavity Option Rough-in
VENTED CAVITY AND KZK INSTALLATIONS ONLY
Nominal 2”x 4” framing used in enclosure framing
#CLW-40 R.3 November 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FRAMING