3.7.2 Vented Cavity and Komfort Zone Kits
Vented Cavity design options and Komfort Zone Kit have specific
framing requirements, mantel requirements, and exterior trim
dimensions. The appliance convection baffle and outer shell plates
must be removed for heat distribution required by cavity framing
designs.
•
See Section 3.7.2.4 Rough-in Wall Enclosure on page 23 for
minimum rough opening dimensions.
•
All minimum required dimensions must be maintained after all
finishing materials are installed.
•
The appliance convection baffle and outer shell plates must be
removed for heat distribution required vented cavity framing
designs and Komfort Zone Kit installations, as shown in Figure
1. Remove the (4) cover plates, (4) screws each. See Figure 3.11.
2. Remove the convection baffle from the appliance. The baffle
is secured by (2) screws right behind the upper edge of the
fireplace opening.
.
Recycle this panel as it is no
longer needed.
•
See Section 4.5 Vented Cavity and KZK Facing and Finishing
Requirements on page 38 for vented cavity facing, finishing
and mantel requirements.
Vented cavity options and Komfort Zone Kits must
remove (4) circle cover plates and convection baffle
Convection
baffle to be
removed
Convection airflow
with
baffle in place
Convection airflow
with
baffle removed
Figure 3.11, Cover Plates and Convection Baffle Removal
Figure 3.10, Air Flow inside Appliance