
30
FIREPLACE SETUP
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#BIR-20-L R.5 June 2020
7.4 Control Board Removal and Installation
WARNING: If burner and/or pilot have been burning,
use appropriate protection to avoid burns or damage
to personal property before removing any components.
DO NOT OPERATE THIS APPLIANCE WITHOUT THE SEALING GASKET
(LOCATED UNDER THE CONTROL BOARD) IN PLACE. IF GASKETING IS
DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water, whether
field or factory made.
7.4.1 Control Board Removal
1. Disconnect electrical power.
2. Locate the manual valve installed by your qualified service
technician.
3. Turn the manual valve clockwise to the OFF position.
4. Remove the safety barrier and glass frame assembly.
5. Remove logs.
6. Remove the back log plate (2) screws.
7. Remove (2) screws on each side of the back burner. Slide the
burner tube venturi to the right to release from the burner
orifice.
8. Remove the front burner from the firebox (4) screws.
9. Remove and save (10) screws securing the control board. Lift
the control board and disconnect the main burner on/off rocker
switch wires. Lift the control module out of the firebox, being
careful not to damage sealing gasket underneath.
7.4.2 Control Board Installation
1. Place the control module in the firebox, aligning the holes in the
control board with the holes in the firebox bottom.
VERIFY SEALING GASKET IS IN PLACE.
2. Reconnect main burner on/off rocker switch wires.
3. Secure the control board to the firebox using (10) screws
previously removed.
4. Reinstall the front burner (4) screws, positioning the burner
venturi over the burner orifice.
5. Reinstall the back burner. Position the burner tube venturi over
the burner orifice. Secure with (2) screws.
6. Reinstall the back log plate (2) screws.
7. Reinstall log set.
8. Reinstall the glass frame assembly and safety barrier.
9. Turn the manual valve counterclockwise to the ON position.
10. Reconnect electrical power.
11. Verify proper log placement, operation of fireplace, and any
electrical components.
Figure 7.5, Control Board Removal and Installation
Front Burner
Back Burner
Back Log Plate