30
VENTING
8.8 Horizontal Vent Heat
Shield Installation
IMPORTANT: The horizontal vent heat shield must be installed
when incorporating minimum horizontal venting.
1. Loosen, but do not remove the (2) attachment screws in front
of the flue collar on the top of the fireplace.
2. Bend the heat shield at perforation to a 90° angle.
3. Slide the (2) slots on horizontal vent heat shield under
previously loosened screws.
4. Re-tighten screws to install.
ATTACHMENT SCREWS
Figure 8.5, Installed Horizontal Heat Shield