FIREPLACE SETUP 

31

9.0  FIREPLACE SETUP

9.1  Hearth Plate and Component 

Access Doors 

9.1.1  Install Hearth Plate and 

Component Access Doors

1.  Install the glass frame assembly. 
2.  Locate the (4) slots on each side of the fireplace metal 

cabinet (2 each side).

3.  Align the notched tabs on each component access door with 

the slots on sides of the metal cabinet. Raise slightly into 
slots and lower into position. 

4.  Install hearth plate. Set the long angled flange of the hearth 

plate behind the access door handles to secure into place.

9.1.2  Remove Hearth Plate and 

Component Access Doors

1.  Remove hearth plate by lifting it up and out of the firebox.
2.  Lift the component access doors up and out of slots.

9.2  Glass Frame Assembly

WARNING: Do not operate this fireplace with the glass removed, 
cracked, or broken. Replacement of the glass assembly, should 
be done by a licensed or qualified service person. 

9.2.1  Remove Glass Frame Assembly

WARNING: Do not remove the glass assembly when hot.

1.  Remove the hearth plate and component access doors.
2.  Use a 7/16” nut driver to remove (3) nuts securing the 

bottom of the glass valance.

3.  Lift the glass frame assembly up and off (3) tabs located at 

the top of the firebox. 

9.2.2  Install Glass Frame Assembly

1.  Align the slots on top of the glass assembly over the tabs at 

the top of the firebox while lowering the bottom of the glass 
assembly into position.

2.  Secure glass frame assembly with (3) nuts previously 

removed.

3.  Reinstall the hearth plate and component access doors.

9.3  Light Kit

CAUTION: Disconnect all electrical power from the fireplace 
before performing this task. 
NOTE: To avoid damage and prolong the life of the halogen 
bulbs, never touch with bare hands. Always use a soft cloth 
when handling. 

1.  Remove the safety barrier and glass frame assembly.
2.  Remove the light access panel on firebox ceiling (2) screws.
3.  Use a 1/4” wrench, loosen, but do not remove the bulb clips 

located inside the light chamber. 

4.  Install (2) halogen bulbs (included in components packet) 

into lamp bases. 

5.  Reposition bulb clips over tips of halogen bulbs and re-

tighten screws. Do not over-tighten. 

6.  Reinstall light access panel on firebox ceiling using (2) 

screws previously removed. 

COMPONENT
ACCESS

HEARTH PLATE LOCATION

Figure 9.1, Locations for Hearth Plate and Component Access Doors

LIGHT ACCESS PANEL - SECURED BY (2) SCREWS

Figure 9.2, Light Access Panel Location

Figure 9.3, Bulb Clips

Содержание ALPHA-36S

Страница 1: ...G FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage This appliance may be installed in an aftermarket permanently located manuf...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...ation 22 7 0 TERMINATION LOCATIONS 23 7 1 Vertical Vent Cap Termination 23 7 2 Minimum Termination Clearances 24 8 0 VENTING 25 8 1 Approved 5 x 8 Vent Systems 25 8 2 Venting Requirements 25 8 3 Use o...

Страница 6: ......

Страница 7: ...tor as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanent...

Страница 8: ...03 kW 24 000 Btu h 7 03 kW Manifold Pressure High 3 8 WC 0 95 kPa 11 WC 2 74 kPa Manifold Pressure Low 1 1 WC 0 27 kPa 2 9 WC 72 kPa Orifice Size DMS 29 49 2 2 1 Altitude Adjustment This appliance ma...

Страница 9: ...ers 1059 1182 1182 593 972 813 135 238 Figure 2 1 Alpha 36 Unit Dimensions TOP LEFT RIGHT FRONT 37 8 99mm 27 692mm 3 4 19mm 38 972mm 48 1238mm 233 8 593mm 9 248mm 13 349mm 93 8 99mm 109 16 268mm 1311...

Страница 10: ...ssong Mfg s barriers for this appliance Only doors certified with the appliance shall be used 2 4 1 Safety Barrier Installation For models AL36A DSFS AL36A MSFS AL36R DSFS AL36R MSFS 1 Locate 2 magnet...

Страница 11: ...the fireplace DO NOT use wood sheetrock et cetera in this zone Top stand off brackets must be formed and attached prior to positioning fireplace into framed opening 1 Remove and save 4 screws securin...

Страница 12: ...unit back stand offs 0 in 0 mm From bottom stand offs 0 in 0 mm Top of unit face to ceiling 30 5 16 in 770 mm Side of finishing edge to adjacent sidewall 6 in 152 mm Unit front to combustibles 36 in...

Страница 13: ...fireplace facing materials If using a hearth adjust the rough opening size as necessary to maintain minimum clearance requirements If masonry is to be used optional prepare the necessary foundation fo...

Страница 14: ...instructions that a television should not be installed on near or above a heat source Television location rests solely on the homeowner It is the homeowner s responsibility that the preferred TV mount...

Страница 15: ...e surround fireplace chase must comply with all clearances as outlined in this manual and be constructed in compliance with local building codes Outside walls should be insulated to prevent cold air f...

Страница 16: ...etal screws 1 Register cover with screws 4 Sheet rock screws 1 Duct collar 3 Flange nuts 1 Fan assembly 1 Strapping cord 1 Fan housing cover plate 3 Wire nuts 1 Speed control mounting bracket 2 Fan wi...

Страница 17: ...allow for sheetrock installation 5 Secure the mounting bracket to framing with the provided 4 sheetrock screws 6 Install the junction box on the wall at desired location The junction box is used to h...

Страница 18: ...speed control through the mounting bracket Secure with the mounting nut 4 Secure mounting bracket to the junction box with the 2 screws provided 5 Center the register cover over the fan housing cover...

Страница 19: ...facing away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flange until parallel with firepla...

Страница 20: ...6 770mm 37 8 99mm 55 1397mm 53 1346mm 51 1295mm 49 1245mm 47 1194mm 17 432mm 15 381mm 13 330mm 11 279mm 9 229mm 12mm THICK NON COMBUSTIBLE SHOWN MANTEL OVERHANG DIMENSIONS ARE BASED OFF TYPICAL 12MM N...

Страница 21: ...ll non combustible framing up to facing flange surrounding the glass frame assembly Do not apply any material beyond this point The glass frame assembly must be removable Non combustible material surr...

Страница 22: ...ssures in excess of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A...

Страница 23: ...r 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27...

Страница 24: ...combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L Cl...

Страница 25: ...uired 3 in 76 mm top clearance to combustibles must be installed for all horizontal vent runs that pass through interior or exterior walls These wall thimble products may be insulated using unfaced in...

Страница 26: ...r ASTM E 136 Table 8 3 NG LPG Minimum Maximum Vertical Terminations Minimum Vertical Length Maximum Vertical Length 4 ft 1219 mm 50 ft 15 2 m VENTING DIAGRAM VERTICAL TERMINATIONS A Stand off Brackets...

Страница 27: ...rminations Minimum Vertical Rise VMIN Minimum Horizontal Run HMIN Maximum Horizontal Run HMAX 18 in 457 mm 9 in 229 mm 20 ft 6 1 m Table 8 5 NG Max Vertical Max Horizontal Combination Maximum Vertical...

Страница 28: ...imum Vertical Rise VMIN Minimum Horizontal Run HMIN Maximum Horizontal Run HMAX 18 in 457 mm 9 in 229 mm 4 ft 1229 mm Table 8 7 LPG Max Vertical Max Horizontal Combination Maximum Vertical Rise Maximu...

Страница 29: ...lant around outer edge of termination box A placing assembly through the wall pass through in exterior wall Place screws through the four holes B securing it in place 4 Form the 5 8 flexible aluminum...

Страница 30: ...ntal venting 1 Loosen but do not remove the 2 attachment screws in front of the flue collar on the top of the fireplace 2 Bend the heat shield at perforation to a 90 angle 3 Slide the 2 slots on horiz...

Страница 31: ...e glass valance 3 Lift the glass frame assembly up and off 3 tabs located at the top of the firebox 9 2 2 Install Glass Frame Assembly 1 Align the slots on top of the glass assembly over the tabs at t...

Страница 32: ...ing instructions and illustrations for proper log placement 1 Align the holes in the bottom of logs 1 through 3 with the mounting pins on the burner Push to seat 2 Position log 4 as shown below 3 Posi...

Страница 33: ...namel firebox liner 4 Firebox insulation panels 3 Exterior enamel panels 4 Screws 1 Remove firebox floor refractory 2 Press together the back insulation and back enamel panel The insulation panels wil...

Страница 34: ...or remove the grounding prong from this plug 10 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes...

Страница 35: ...ill not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit condensation will...

Страница 36: ...osition for remote control operation of the main burner and fireplace features 11 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Страница 37: ...imately 2 seconds move the switch to the ON position The ignition sequence will start again 11 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After appr...

Страница 38: ...lot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD screen wi...

Страница 39: ...be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and s...

Страница 40: ...s will operate at previous setting There is no delay in start up or stop time 11 8 9 Accent Light Kit if applicable The light intensity can be adjusted through 6 levels 1 Press the mode key to index...

Страница 41: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Страница 42: ...nturi Openings Fuel Air Shutter Opening Natural Gas 1 8 3 mm OPEN LP Gas 5 8 15 mm OPEN 12 2 1 1 Venturi Adjustment NOTE If soot is present on the glass check log positioning before adjusting the vent...

Страница 43: ...or ghost after opening the restrictor and verifying correct vent installation shut off the gas supply and call a qualified service technician 12 2 2 1 Restrictor Installation 1 Remove the safety barr...

Страница 44: ...o LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe or a...

Страница 45: ...uri air shutter may need to be opened slightly to allow more air into the gas mix Refer to Section 12 2 1 Burner Venturi on page 42 Incorrect vent cap installation Adjust if necessary Vent cap blockag...

Страница 46: ...e vent air intake system is disassembled for any reason reinstall per instructions provided with installation Refer to Section 8 0 Venting on page 25 Performed by Qualified Service Person Frequency An...

Страница 47: ...K AL36L S Pilot Assembly LPG 700 551 1 Conversion Kit LPG LCK AL36L S Transmitter Remote Control 700 408 Burner Tube AL36 L 035 Pilot Orifice NG 700 094 Burner Cover AL36L 350 Pilot Orifice LPG 700 16...

Страница 48: ...48...

Страница 49: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Страница 50: ......

Страница 51: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Отзывы: