2.0 SPECIFICATIONS
2.1 Btu & Efficiency Specifications
EPA Certification #
214-19
EPA Certified Emissions
1.22 grams per hour
LHV Tested Efficiency
70.6%
HHV Tested Efficiency
66.0%
Burn time (length of high fire test / low
fire test)
2 - 9 hours
EPA Btu Output
12,850-36,231 Btu/hr
*Peak Btu/hour Output
49,133 Btu/hr
**Optimum Efficiency
73.32
Fuel
Cord wood
*A peak BTU out of the appliance is calculated using the maximum first
hour burn rate from the High EPA Test and the BTU content of cordwood
times the efficiency.
**Optimum efficiency is calculated using the medium fire test burn data,
BTU content of the cordwood, and the best case moisture content of the
cordwood.
This wood heater has a manufacturer-set minimum low burn rate that
must not be altered. It is against federal regulations to alter this setting
or otherwise operate this wood heater in a manner inconsistent with
operating instructions in this manual.
2.2 Electrical Specifications
Code approved line voltage wiring 14 gauge or better must be used
when wiring the optional #600-1 fan kit assembly. Refer to local codes
for specific requirements.
This appliance must be electrical grounded and connected with local
codes, or in the absence of local codes, with the
National Electrical
Code, ANSI/NFPA 70 Current Edition
, or the
Canadian Electrical Code CSA
C22.1.