Korenix JetRock Series Скачать руководство пользователя страница 32

 

[email protected] 

31

 

TFTP Server 

In this mode, the switch acts as the TFTP client. Before you 
do so, make sure that your TFTP server is ready. Then, type 
in  the  TFTP  Server  IP  address.  This  mode  can  be  used  in 
both Web UI and CLI. 

TFTP Server IP Address 

Key in the IP address of your TFTP Server here. 

Firmware File Name 

View the file name of the new firmware. 

The UI also shows you the latest firmware version and build date. Please check 
the version number after you reboot the switch. 
The following Web UI is for Firmware Upgrade - Local File mode.   

 

 

  Click on the Folder icon to select the correct firmware you want to upgrade 

The following Web UI is for Firmware Upgrade – TFTP Server mode. 

 

 

Type  in  the  IP  address  of  the  TFTP  Server  and  the  Firmware  File  Name.  Then 
click the Upgrade button to start the process. 
After finishing the transmission of the firmware, the system will copy the 
firmware file and replace the firmware in the flash. The CLI will show until the 
process is finished.

 

Содержание JetRock Series

Страница 1: ...User Manual Configuration First Edition Sep 2008 www korenix com ...

Страница 2: ...al in this document is for product information only and is subject to change without notice While reasonable efforts have been made in the preparation of this document to assure its accuracy Korenix assumes no liabilities resulting from errors or omissions in this document or from the use of the information contained herein Korenix reserves the right to make changes in the product design without n...

Страница 3: ...mmercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The us...

Страница 4: ... 2 4 2 SSH Secure Shell 11 3 FEATURE CONFIGURATIONS 14 3 1 INTRODUCTION TO COMMAND LINE INTERFACE CLI 14 3 2 BASIC SETTINGS 18 3 2 1 Switch Setting 19 3 2 2 Admin Password 20 3 2 3 IP Configuration 20 3 2 4 Time Setting 21 3 2 5 DHCP Server and DHCP Option 82 Relay Agent 25 3 2 6 Backup and Restore 28 3 2 7 Firmware Upgrade 30 3 2 8 Factory Default 32 3 2 9 System Reboot 33 3 2 10 CLI Commands for...

Страница 5: ...LTERING 63 3 7 1 IGMP Snooping 63 3 7 2 IGMP Query 64 3 7 3 CLI Commands of the Multicast Filtering 65 3 8 SNMP 66 3 8 1 SNMP Configuration 67 3 8 2 SNMP v3 Profile 67 3 8 3 SNMP Traps 68 3 8 4 CLI Commands for SNMP 69 3 9 SECURITY 70 3 9 1 IP Security 70 3 9 2 CLI Commands for Security 71 3 10 WARNING 71 3 10 1 Fault Relay Setting 72 3 10 2 Event Selection 74 3 10 3 SysLog Configuration 76 3 10 4...

Страница 6: ...s for Save to Flash 87 3 14 LOGOUT 87 3 14 1 CLI Commands for Logout 87 APPENDIX A KORENIX PRIVATE MIB 88 APPENDIX B TECHNICAL DATA 89 B 1 JETNET 4506 RJ 89 B 2 JETNET 4506 M12 91 B 3 JETNET 3006 RJ 93 B 4 JETNET 3006 M12 94 B 5 JETNET 3706 RJ 95 FURTHER SUPPORT 97 ...

Страница 7: ...eeds 1 1 Product Features JetRock models have the following features y IP67 IP68 enclosure protection y Robust connection against shock and vibration y Store and forward switch technology y Broadcast storm filtering y 2K MAC address table y Transfer packet size from 64 to 1536 bytes y JetNet 3706 RJ is IEEE 802 3af PoE enabled The managed models JetNet 4506 RJ and JetNet 4506 M12 provide a large r...

Страница 8: ...ded Console Cable 1 1 y Rugged RJ45 Field Assembleable Connecter 6 6 6 y Wall Mount Screws Washer and Nuts 4 4 4 4 4 y 1 1 Wall Mount Drilling Template 1 1 1 1 1 y Quick Installation Guide 1 1 1 1 1 y Documentation and Software CD ROM 1 1 1 1 1 1 3 About This Manual The following manuals are included as PDF files on the CD ROM y User manual Hardware Installation includes information to install all...

Страница 9: ...edded HTTP web pages 2 1 Preparation for Console Management Connect to the device by the M12 on DB9 console cable 1 Go to Start Program Accessories Communication Hyper Terminal 2 Give a name to the new console connection 3 Choose the COM name 4 Select correct serial settings The serial settings for the JetRock are Baud Rate 9600 Parity Check None Data Bit 8 Stop Bit 1 5 After connected you will se...

Страница 10: ...agement JetRock provides both HTTP Web interface and Secure HTTPS Web interface for management The web page uses JavaScript which allows you to use a standard web browser such as Microsoft Internet Explorer or Mozilla FireFox to configure the switch from anywhere while connected to the network 2 3 1 HTTP Web Interface 1 Launch web browser 2 Connect URL of the device The URL of the device is its IP...

Страница 11: ...anything after 30 seconds Re login if this occurs 2 3 2 HTTPS Web Interface HTTPS provides secure network connection The username password and all the commands and responses are encrypted against peeping 1 Launch web browser 2 Connect URL of the device The URL of the device is its IP address for example https 192 168 10 1 for the default IP address or the IP address you assigned to it 3 A window w...

Страница 12: ...erates in client server architecture While the device acts as the SSH server you need a SSH client application before making a SSH connection to the switch There are many SSH clients you can find on the internet such as PuTTY We take PuTTY as an example to describe how to use SSH Note PuTTY Copyright 1997 2006 Simon Tatham Download PuTTY http www chiark greenend org uk sgtatham putty download html...

Страница 13: ... Industrial Ethernet Switch 12 www korenix com 2 After clicking Open you will see the cipher information in the popup screen Press Yes to accept the Security Alert 3 After a few seconds the SSH connection opens ...

Страница 14: ...The default login name and password is admin admin 5 All the commands you see in SSH are the same as the commands you see via console The next chapter will introduce in detail how to use the command line to configure the switch ...

Страница 15: ...e in the User EXEC mode You can ping telnet remote device and show some basic information Types enable to enter the next mode and exit to logout Below is a full command list Privileged EXEC mode Type enable in the User EXEC mode to enter the Privileged EXEC mode In this mode the system allows you to view current configurations reset to default reload the switch show the system s information save a...

Страница 16: ...t interface configuration mode Switch config access list Add an access list entry administrator Administrator account setting arp Set a static ARP entry clock Configure time of day clock default Set a command to its defaults end End current mode and change to enable mode exit Exit current mode and down to previous mode hostname Set system s network name interface Select an interface to configure i...

Страница 17: ...scription duplex Specifies the duplex mode of operation for a port end End current mode and change to enable mode exit Exit current mode and down to previous mode flowcontrol Sets the flow control value for an interface list Print command list loopback Specifies the loopback mode of operation for a port mac MAC interface commands mdix Enables mdix state of a given port no Negate a command or set i...

Страница 18: ...ter interface configuration mode Switch config Port Interface configuration In this mode you can configure port related settings Enter Type interface IFNAME in global configuration mode Exit Type exit or Ctrl Z to global configuration mode Type end to privileged EXEC mode Switch config if VLAN Interface Configuration In this mode you can configure settings for specific VLAN Enter Type interface VL...

Страница 19: ... a locked screen Exits config An alert age appears when multip administrator is in configuration mode change the settings Only one administrator is allowed to configure the switch at a time 3 2 Basic Settings ou with instructions on how to configure switch information set the IP address and configure the username and password of This section provides y the system It also allows you to upgrade the ...

Страница 20: ...hysical location You can input up to 64 characters System Contact Specify contact people Enter the name e mail address or other information about the administrator You can input up to 64 characters System OID Set the SNMP object ID of the switch You can follow the path to find its private MIB in the MIB browser Note When you attempt to view a private MIB you should compile private MIB files into y...

Страница 21: ... username and password to enhance security The following figure is the Web UI for Admin Password Username Key in a new username The default setting is admin Password Key in a new password The default setting is admin Confirm Password Re enter the new password to confirm it Once you finish configuring the settings click the Apply button to apply your configuration The following figure is the popup ...

Страница 22: ...r the IP address If DHCP Client function is enabled you don t need to assign the subnet mask The default Subnet Mask is 255 255 255 0 Note In the CLI we use the enabled subnet mask to represent the number displayed in the web UI For example 8 stands for 255 0 0 0 16 stands for 255 255 0 0 24 stands for 255 255 255 0 Gateway Assign the gateway for the switch The default gateway is 192 168 10 254 No...

Страница 23: ...elect the Time Setting Source to NTP client can let device enable the NTP client It allow the switch get time from 2 different NTP servers The system will send request packet to acquire current time from the NTP server Time zone Select the time zone where the switch is located For your reference the following table lists the time zones of different locations The default time zone is GMT Greenwich ...

Страница 24: ...rgetown 21 GMT 03 00 Greenland 22 GMT 02 00 Mid Atlantic 23 GMT 01 00 Azores 24 GMT 01 00 Cape Verde Is 25 GMT Casablanca Monrovia 26 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London 27 GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna 28 GMT 01 00 Belgrade Bratislava Budapest Ljubljana Prague 29 GMT 01 00 Brussels Copenhagen Madrid Paris 30 GMT 01 00 Sarajevo Skopje Sofija Vilnius Warsa...

Страница 25: ...hongqing Hong Kong Urumqi 57 GMT 08 00 Irkutsk Ulaan Bataar 58 GMT 08 00 Kuala Lumpur Singapore 59 GMT 08 00 Perth 60 GMT 08 00 Taipei 61 GMT 09 00 Osaka Sapporo Tokyo 62 GMT 09 00 Seoul 63 GMT 09 00 Yakutsk 64 GMT 09 30 Adelaide 65 GMT 09 30 Darwin 66 GMT 10 00 Brisbane 67 GMT 10 00 Canberra Melbourne Sydney 68 GMT 10 00 Guam Port Moresby 69 GMT 10 00 Hobart 70 GMT 10 00 Vladivostok 71 GMT 11 00 ...

Страница 26: ...lt gateway and other IP parameters to the client This switch can act as a DHCP server which helps to reduce system administration workload allowing devices to be added to the network with little or no manual configuration DHCP Server Enable or Disable DHCP Server function A switch acts as a DHCP server will assign a new IP address to link partners DHCP Server configuration After selecting to enabl...

Страница 27: ...device Add or remove an IP address from the Excluded Address List by clicking the Add or Remove button Manual Binding The binding between a MAC address and an IP address can be fixed You can type in the specified IP and MAC address and then click the Add button to add a new MAC IP address binding rule for a specified link partner like PLC or any device without DHCP client function To remove from t...

Страница 28: ...HCP relay agent to include information about itself when forwarding client originated DHCP packets to a DHCP server The DHCP server can use this information to implement IP address or other parameter assignment policies This feature gives you the option of always assigning the same IP address to any device which is connected to a particular location port of a device on the LAN This switch is able ...

Страница 29: ...ration file Local File mode and TFTP Server mode Local File mode In this mode the switch acts as the file server User browses the target folder and gives a file name to backup the configuration User can also browse the target folder and select existing configuration files to restore the configuration back to the switch This mode is only provided by Web UI CLI is not supported TFTP Server mode In t...

Страница 30: ...on to select the target file you want to backup restore Note The folders of the path to the target file do not allow you to input space key Technical Tip Default Configuration File The switch provides the default configuration file in the system You can use the Reset button Reload command to reset the system Running Configuration File The CLI allows you to view the latest setting running on the sy...

Страница 31: ... suggest you use the latest firmware before installing the switch Note The system will automatically reboot after you finish upgrading the new firmware Please inform all attached users before doing this The following figure is the Web Main UI for Firmware Upgrade There are 2 modes for users to backup restore the configuration file Local File mode and TFTP Server mode Local File mode In this mode t...

Страница 32: ...st firmware version and build date Please check the version number after you reboot the switch The following Web UI is for Firmware Upgrade Local File mode Click on the Folder icon to select the correct firmware you want to upgrade The following Web UI is for Firmware Upgrade TFTP Server mode Type in the IP address of the TFTP Server and the Firmware File Name Then click the Upgrade button to star...

Страница 33: ...The Web UI figure for Reset to Default Factory Default The following figure is the popup alert screen to confirm the command Click Yes to reset the system The following UI is a popup message screen to show you that the reset is complete Click OK to close the screen Then go to the Reboot page to reboot the switch Click OK The system will then automatically reboot the device Note If you have already...

Страница 34: ...eboot the system Click the Reboot button to reboot your device Note Remember to click the Save button to save your settings Otherwise the settings you made will be gone once the switch is powered off Below is the Main screen for Reboot Below is the popup alert screen to request confirmation for the Switch Reboot Click Yes to reboot the switch The popup message screen below appears when rebooting t...

Страница 35: ...care korenix com Switch show version 0 31 20061218 Switch show hardware mac MAC Address 00 12 77 FF 01 B0 Admin Password User Name and Password Switch config administrator NAME Administrator account name Switch config administrator admin Command incomplete Switch config administrator orwell PASSWORD Administrator account password Switch config administrator orwell orwell Change administrator accou...

Страница 36: ...e By typing clock timezone you can see the timezone list Then choose the number of the timezone you want to select Display Switch sh ntp associations 1 192 168 10 100 2 192 168 10 101 Switch show clock Sun Jan 1 04 14 19 2006 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London Switch show clock timezone clock timezone 26 GMT Greenwich Mean Time Dublin Edinburgh Lisbon London DHCP Server DHCP se...

Страница 37: ...f ip dhcp client renew Display Switch show running config interface vlan1 ip dhcp client no shutdown DHCP Option 82 Relay Agent DHCP server and Relay Agent Switch config router dhcp Switch config dhcp service dhcp Switch config dhcp ip dhcp relay information option The DHCP server the relay agent forwards to Switch config dhcp ip dhcp helper address 192 168 20 1 Relay policy drop Switch config dhc...

Страница 38: ...up Configuration Switch show startup config Show Running Configuration Switch show running config Firmware Upgrade Firmware Upgrade Switch archive download sw overwrite tftp 192 168 10 33 JetNet 4506 RJ bin Firmware upgrading don t turn off the switch Tftping file JetNet 4506 RJ bin Firmware upgrading Firmware upgrade success Rebooting Factory Default Factory Default Switch reload default config f...

Страница 39: ... Ethernet Port 1 6 fa1 fa6 Auto Negotiation 10M Full Duplex 10 Full 10M Half Duplex 10 Half 100M Full Duplex 100 Full and 100M Half Duplex 100 Half The default mode is Auto Negotiation mode Flow Control Symmetric or disable the flow control function Symmetric means that you need to activate the flow control function of the remote network device in order to let the flow control of that correspondin...

Страница 40: ...nt port status A description of each column is as follows Port Port interface number Type 100BASE for Fast Ethernet port Link Link status Up Link UP Down Link Down State Enable State is enabled Disable The port is disabled by user configured Speed Duplex Current working status of the port Flow Control The state of the flow control 3 3 3 Rate Control ...

Страница 41: ...6Kbps 512Kbps 1024Kbps 2048Kbps 4096Kbps and 8192Kbps To enable rate control function please click the Apply button to apply the configuration 3 3 4 Command Lines for Port Configuration Feature Command Line Port Control Port Control State Switch config if shutdown Disable port state Port1 Link Change to DOWN interface fastethernet1 is shutdown now Switch config if no shutdown Enable port state Por...

Страница 42: ...gress Filtering Disabled Acceptable Frame Type All Port Security Disabled Auto Negotiation Disable Loopback Mode None STP Status forwarding Default CoS Value for untagged packets is 0 Mdix mode is Disable Medium mode is Copper Note Administrative Status Port state of the port Operating status Current status of the port Duplex Duplex mode of the port Speed Speed mode of the port Flow control Flow C...

Страница 43: ...ial applications for networks to continue working non stop This switch supports standard RSTP Multiple Super Ring Rapid Dual Homing and Legacy Super Ring Client modes Multiple Super Ring MSR technology is Korenix s 3rd generation Ring redundancy technology This is patented and protected by Korenix and is used all over the world MSR ranks the fastest restore and failover time 0 ms for restore and l...

Страница 44: ...n select the best path primary and block the other path s It will also keep track of the blocked path s in case the primary path fails Spanning Tree Protocol STP introduced a standard method to accomplish this It is specified in IEEE 802 1D 1998 Later Rapid Spanning Tree Protocol RSTP was adopted and represents the evolution of STP providing for a much faster spanning tree convergence after a topo...

Страница 45: ...represents the time that a bridge will wait without receiving Spanning Tree Protocol configuration messages before attempting to reconfigure If this switch is not the root bridge and if it has not received a hello message from the root bridge in the amount of time equal to the Max Age then this switch will reconfigure itself as a root bridge Once two or more devices on the network are recognized a...

Страница 46: ... Priority Enter a value between 0 and 240 using multiples of 16 This is the value that decides which port should be blocked by priority in a LAN Admin P2P Some of the rapid state transitions that are possible within RSTP depend upon whether the port of concern can only be connected to another bridge i e it is served by a point to point LAN segment or if it can be connected to two or more bridges i...

Страница 47: ...y is to form a ring or loop Typically the managed switches are connected in a series and the last switch is connected back to the first one In such a connection you can use Korenix Super Ring and Rapid Super Ring technology Super Ring is Korenix s 1st generation ring redundancy technology released with JetNet 4000 4500 Rapid Super Ring RSR is Korenix s 2nd generation Ring redundancy technology The...

Страница 48: ...eld is left blank the name of this ring will automatically name with RingID Note Only JetNet 5000 series and upper can create more than one ring This page allows you to enable the settings for Rapid Super Ring Ring Configuration ID Once a Ring is created This appears and can not be changed Name This field will show the name of the Ring If it is not filled in when creating it will be automatically ...

Страница 49: ...aster of a Ring then it determines the blocking port The Port with higher Path Cost in the two ring Ports will become the blocking port if the Path Cost is the same the port with larger port number will become the blocking port Ring Port2 Assign another port for ring connection Path Cost Change the Path Cost of Ring Port2 Rapid Dual Homing Rapid Dual Homing is an important feature of Korenix 3rd g...

Страница 50: ...is Switch is RM or nonRM Status If this field is Normal which means the redundancy is approved If any one of the link in this Ring is broken then the status will be Abnormal RM MAC The MAC address of Ring Master of this Ring It helps to find the redundant path Blocking Port This field shows which port of RM is blocked Role Transition Count This means how many times this switch has changed its Role...

Страница 51: ...config spanning tree hello time 2 Forward Delay Switch config spanning tree forward time 4 30 Valid range is 4 30 seconds Switch config spanning tree forward time 15 algorithm timer Switch config spanning tree algorithm timer forward delay max age hello time Switch config spanning tree algorithm timer 15 20 2 Path Cost Method Switch config if spanning tree cost method long specifies 32 bit based v...

Страница 52: ...6 Bridge Times max age 10 sec hello time 2 sec forward delay 15 sec Aging time 300 Port Role Port State Cost Prio Nbr Type fa6 Designated Forwarding 200000 128 6 Auto RST fa7 Root Forwarding 200000 128 7 Shared STP RSTP Summary Switch show spanning tree summary Switch is in rapid stp mode BPDU skewing detection disabled for the bridge Backbonefast disabled for bridge Summary of connected spanning ...

Страница 53: ... 4096 address 0012 7701 0386 Designated bridge has priority 4096 address 0012 7701 0386 Designated Port ID is 128 1 Root Path Cost is 0 Timers message age 4 sec forward delay 0 sec Forwarding State Transmit count 2 BPDU sent 624 received 3600 TCN sent 0 received 0 Rapid Super Ring Create or configure a Ring Switch config multiple super ring 1 Ring 1 created Switch config super ring plus Note 1 is ...

Страница 54: ... Switch config super ring plus rapid dual homing port IFLIST Interface name ex fastethernet1 or fa8 auto detect up link auto detection IFNAME Interface name ex fastethernet1 or fa4 Switch config super ring plus rapid dual homing port fa3 fa5 6 set Dual Homing port success Switch config multiple super ring rapid dual homing port fa1 priority default Set Rapid Dual Homing port priority success Note ...

Страница 55: ... determines the membership of a frame by examining the configuration of the port that receives the frame or by reading the frame s VLAN tag A four byte field in the header is used to identify the VLAN This VLAN identification indicates which VLAN the frame belongs to If the frame has no tag header the switch checks the VLAN setting of the port that received the frame If the switch has been configu...

Страница 56: ...4094 But 0 and 4095 are reserved You can not input these 2 PVIDs 1 is the default value 2 to 4094 are valid and available in this column Type the PVID you d like to configure here Allow Send To This column defines the port that traffic could be forwarded to You can click the icon to join the port as a Port Based VLAN group The following figure is the Web user interface for Port Based VLAN configur...

Страница 57: ...witch The ports where the frame comes in to this port are allowed to forward to switchport port based vlan egress ports IFLIST ex port 1 can forward packet to port 2 3 Switch config if switchport port based vlan egress ports fa2 fa3 Set port based vlan success Assign default PVID for this port switchport trunk native vlan VID ex assign VID 1 to port 1 Switch configure terminal Switch config interf...

Страница 58: ...trict Priority scheme which follows 802 1p COS tag and IPv4 TOS DiffServ information to prioritize the traffic of your industrial network 3 6 1 QoS Setting Queue Scheduling Use an 8 4 2 1 weighted fair queuing scheme This is also known as WRR Weight Round Robin JetNet will follow the 8 4 2 1 rate to process the packets in a queue from the highest priority to the lowest For example the system will ...

Страница 59: ...ing rule Port Based The port priority will follow the queue priority that you have assigned The default priority type is CoS Only The system will provide a default CoS Queue table that you can refer to for the next command After configuring click the Apply button to enable the settings 3 6 2 CoS Queue Mapping This area is where you can set CoS values to the Physical Queue mapping table Since the s...

Страница 60: ...pping is a table which maps the DSCP values to the physical queues There are 4 physical queues treating outgoing frame in 4 priorities lowest low middle and high Changing the mapping between the DSCP value and the priority queue for the quality of service you need After configuring click the Apply button to enable the settings ...

Страница 61: ...ans fast Ethernet port 1 Port Setting Trust Mode CoS Only Switch config interface fa1 Switch config if qos trust cos The port trust is set CoS only ok Port Setting Trust Mode CoS Frist Switch config interface fa1 Switch config if qos trust cos first The port trust is set CoS first ok Port Setting Trust Mode DSCP Only Switch config interface fa1 Switch config if qos trust dscp The port trust is set...

Страница 62: ... 0 CoS Queue Mapping Format Switch config qos cos map PRIORITY Assign an priority 7 highest Switch config qos cos map 1 QUEUE Assign an queue 0 3 Note qos cos map priority_value queue_value Map CoS 0 to Queue 1 Switch config qos cos map 0 1 The CoS to queue mapping is set ok Map CoS 1 to Queue 0 Switch config qos cos map 1 0 The CoS to queue mapping is set ok Map CoS 2 to Queue 0 Switch config qos...

Страница 63: ...map 7 3 The CoS to queue mapping is set ok Display CoS Queue mapping Switch sh qos cos map CoS to Queue Mapping CoS Queue 0 1 1 0 2 0 3 1 4 2 5 2 6 3 7 3 DSCP Queue Mapping Format Switch config qos dscp map PRIORITY Assign an priority 63 highest Switch config qos dscp map 0 QUEUE Assign an queue 0 3 Note qos dscp map priority_value queue_value Map DSCP 0 to Queue 1 Switch config qos dscp map 0 1 T...

Страница 64: ...P Snooping manages multicast traffic by making use of switches routers and hosts that support IGMP Enabling IGMP Snooping allows the ports to detect IGMP queries report packets and manage multicast traffic through the switch IGMP has three fundamental types of messages as shown below Message Description Query A message sent from the querier an IGMP router or a switch which asks for a response from...

Страница 65: ...button to refresh the table 3 7 2 IGMP Query This page allows user to configure the IGMP Query feature Since IGMP Query can only be enabled on the management VLAN If you want to run IGMP Snooping feature in several VLANs you should notice that whether each VLAN have their own IGMP Querier The IGMP querier periodically sends query packets to all end stations on the LANs or VLANs that are connected ...

Страница 66: ...nds of the Multicast Filtering Feature Command Line IGMP Snooping IGMP Snooping Global Switch config ip igmp snooping IGMP snooping is enabled globally Please specify on which vlans IGMP snooping enables Disable IGMP Snooping Global Switch config no ip igmp snooping IGMP snooping is disabled globally ok Display IGMP Snooping Setting Switch sh ip igmp snooping IGMP snooping is globally enabled Disp...

Страница 67: ...se Time Switch config int vlan 1 Go to management VLAN Switch config if ip igmp Switch config if ip igmp query max response time 15 Change query max response time to 15 seconds default value is 10 seconds Disable Switch config int vlan 1 Switch config if no ip igmp Display Switch sh ip igmp interface vlan1 enabled Yes version IGMPv2 query interval 125s query max response time 10s Switch show runni...

Страница 68: ...ges Read Only and Read Write With Read Only privileges you will only have the ability to read the values in the MIB tables The default community string is set to Public With Read and Write privileges you will have the ability to read and set the values in the MIB tables The default community string is set to Private The switch supports up to 4 community strings Enter the community string and selec...

Страница 69: ... to five Federal Information Processing Standard approved algorithms for computing a condensed digital representation You need to configure SNMP v3 parameters for your SNMP tool with the same authentication method Authentication Password The SNMP v3 user authentication password DES Encryption Password The password of SNMP v3 user DES Encryption 3 8 3 SNMP Traps SNMP Trap is a notification feature ...

Страница 70: ...Trap Enable Trap Switch config snmp server enable trap Set SNMP trap enable ok SNMP Trap Server IP without specific community name Switch config snmp server host 192 168 10 33 SNMP trap host add OK SNMP Trap Server IP with version 1 and community Switch config snmp server host 192 168 10 33 version 1 private SNMP trap host add OK Note private is the community name version 1 is the SNMP version SNM...

Страница 71: ...version 1 admin 3 9 Security By IP Security you are able to set up specific IP addresses to perform authorization for management access to the switch via web browser Telnet or SNMP Once you have finished configuring the settings click the Apply button to apply your configuration 3 9 1 IP Security Add Security IP You can assign any PC as an authenticated workstation by adding a PC s IP address into...

Страница 72: ... Set ip security enable ok Switch config ip security host 192 168 10 33 Add ip security host 192 168 10 33 ok Display Switch show ip security ip security is enabled ip security host 192 168 10 33 3 10 Warning This switch provides several types of warning features for remote monitoring and a real time alert mechanism These features include a System Log for local and remote servers SMTP E mail alert...

Страница 73: ...elay 1 Check the box Relay 1 and then select the Event Type and its parameters Event Type You will be given the following options Dry Output Power Failure Link Failure Ping Failure and Super Ring Failure Each event type has its own parameters A Relay can be related one event type detailed below Dry Output On Period Sec Type in the amount of time you would like Relay Output to be on This can range ...

Страница 74: ...or You may select multiple ports When the selected ports are unlinked the system will short Relay Output and light the DO LED Ping Failure IP Address Enter the IP address of the target device you want to ping Reset Time Sec Enter the amount of time after ping has failed that you would like the relay output to turn off Hold Time Sec Enter the amount of time after ping has failed and relay output ha...

Страница 75: ... and the Hold Time is set to 40 sec The system will turn the Relay Output and Alarm LED off after ping has failed for 10 seconds Reset Time The system will turn the Relay Output and alarm LED on again after 40 seconds Hold Time The change of state of a Relay Output Ping Failure Event see the chart below Super Ring Failure Select Super Ring Failure When the Rapid Super Ring topology is changed the ...

Страница 76: ... incorrect password SNMP Community String is entered Time Synchronize Failure Time Synchronize Failure Fault Relay The DO Fault Relay is on Super Ring Topology Changes Master of Super Ring has changed or backup path is activated Port Event Warning Event is sent when Link Up The port is connected to another device Link Down The port is disconnected e g the cable is pulled out or the opposing device...

Страница 77: ...he selected occurrences selected on the Event Selection page to the System Log server that you have assigned Both The 2 modes mentioned above can be enabled at the same time When enabling Local or Both modes you can monitor the system logs in Monitor and Diag Event Log page Once you have finished configuring the settings click the Apply button to apply your configuration 3 10 4 SMTP Configuration ...

Страница 78: ...s to receive email alarm Rcpt E mail Address 1 The first email address to receive email alert Max 40 characters Rcpt E mail Address 2 The second email address to receive email alert Max 40 characters Rcpt E mail Address 3 The third email address to receive email alert Max 40 characters Rcpt E mail Address 4 The fourth email address to receive email alert Max 40 characters Once you have finished co...

Страница 79: ...reset 1 65535 reset time Switch config relay 1 ping 192 168 10 33 reset 60 0 65535 hold time to retry Switch config relay 1 ping 192 168 10 33 reset 60 60 Port Link Failure Switch config relay 1 port PORTLIST port list Switch config relay 1 port fa1 5 Power Failure Switch config relay 1 power 1 2 power id Switch config relay 1 power 1 Switch config relay 1 power 2 Super Ring Failure Switch config ...

Страница 80: ...1 or gi8 Switch config warning event linkup fa5 Set fa5 link up event enable ok Display Switch show warning event Warning Event Cold Start Enabled Warm Start Disabled Authentication Failure Disabled Link Down fa4 5 Link Up fa4 5 Power Failure Super Ring Topology Change Disabled Fault Relay Disabled Syslog Configuration Local Mode Switch config log syslog local Server Mode Switch config log syslog ...

Страница 81: ... set disable ok Disable Authentication Switch config no smtp server authentication SMTP Email Alert set Authentication disable ok Dispaly Switch sh smtp server SMTP Email Alert is Enabled Server 192 168 10 100 Account admin korenix com Authentication Enabled Username admin Password admin SMTP Email Alert Receipt Receipt 1 korecare korenix com Receipt 2 Receipt 3 Receipt 4 3 11 Monitoring and Diagn...

Страница 82: ...ions users may need to type the static Unicast MAC address into its MAC address table On this page you can type in the MAC Address format xxxx xxxx xxxx and select its VID and Port ID Click the Add buttonto add it to the MAC Address table MAC Address Table In the MAC Address Table you can see all the MAC Addresses learned by the switch fabric The packet types include Management Unicast Static Unic...

Страница 83: ...icast MAC addresss will be updated to the MAC address table Click the Apply button to change the value 3 11 2 Port Statistics This page summarizes the operational statistics for each port The statistics include Link Type Link State Rx Good Rx Bad Tx Good and Collision Rx means the received packets while Tx means the transmitted packets The statistics can just show Rx Good and Tx Good or Rx Bad and...

Страница 84: ...nts in the local log table This page shows the log table The entries include the index and data time and content of the occurrences Click the Clear button to delete the entries Click the Reload button to refresh the table 3 11 4 Ping Utility This page provides Ping Utility for users to ping remote devices and to check whether the device is alive or not Type the target IP address of the target devi...

Страница 85: ...set ok Note rule mac address table static MAC_address VLAN VID interface interface_name Add Multicast MAC address Switch config mac address table multicast 0100 5e01 0101 vlan 1 interface fa1 6 Adds an entry in the multicast table ok Note rule mac address table multicast MAC_address VLAN VID interface_list interface_name range Show MAC Address Table All types Switch show mac address table UNICAST ...

Страница 86: ... Interface fastethernet1 is enable connected which has Inbound RxGood 1292 Outbound TxGood 1978 Bad Collision Mode Switch config rmon statistics counter mode error collisions Set RMON statistics counter mode to RxError and TxCollisions mode Good Mode Switch config rmon statistics counter mode good Set RMON statistics counter mode to RxGood and TxGood mode Event Log Display Switch show event log 1 ...

Страница 87: ...ndicates status of power and link status 3 13 Save to Flash Save Configuration allows you to save any configuration you just made to the Flash Powering off the switch without clicking Save Configuration will cause loss of new settings After selecting Save Configuration click the Save to Flash button to save your new configuration ...

Страница 88: ... Building Configuration OK 3 14 Logout The switch provides 2 logout methods Your web connection will log out if you do not input a command for 30 seconds The Logout command allows you to manually log out the web connection Click Yes to logout and No to go back to the configuration page 3 14 1 CLI Commands for Logout Feature Command Line Logout Switch exit Switch exit ...

Страница 89: ...enix provides privates MIB which includes both the features of standard MIBs and all the proprietary functions For your convenience the structure of the private MIB is designed to be the same as the structure of web interface With the private MIB you can configure the device through SNMP very easily Find private MIBs in the product CD or download from the Korenix Web site www korenix com ...

Страница 90: ...ary functions SNMP MIB RFC 1213 MIBII RFC 1493 Bridge MIB RFC 1757 RMON MIB RFC 2674 VLAN MIB RFC 1643 Ethernet like MIB RFC1215 Trap MIB Korenix Private MIB Firmware upgrade TFTP Local file and JetView System Log 1000 system entries for system or remote log server Event Alarm Relay 1A 24V Dry Relay Contact output for Super Ring failure port link down System power events Quality of Service Quality...

Страница 91: ...wer failure occurred Red RM Ring Manager Green Power Requirements Power Consumption Operating Voltage 12 to 48V DC Power consumption max 10 Watts 48V Mechanical Protection class IP67 Installation Wall mount Case Aluminum metal case Dimension 213 6 mm H x 106 0 mm W x 56 5 mm D Weight 1090 g without package Environmental Operating Temperature 25 70OC Storage Temperature 40 85OC Regulatory Approvals...

Страница 92: ...IB RFC1215 Trap MIB Korenix Private MIB Firmware upgrade TFTP Local file and JetView System Log 1000 system entries for system or remote log server Event Alarm Relay 1A 24V Dry Relay Contact output for Super Ring failure port link down System power events Quality of Service Quality of Service determined by port Tag or IPv4 Type of Service Class of Service IEEE802 1p class of service with 4 priorit...

Страница 93: ...nsumption max 10 Watts 48V Mechanical Protection Class IP68 Installation Wall mount Case Aluminum metal case Dimension 213 6 mm H x 106 0 mm W x 56 5 mm D Weight 1110 g without package Environmental Operating Temperature 25 70OC Storage Temperature 40 85OC Regulatory Approvals DNV pending EN 50155 Railway compliance Safety CE EN60950 EMI FCC Class A CE EN55022 2003 Class A CE EN61000 3 2 2001 Harm...

Страница 94: ...cable 100Base TX 4 pair UTP STP Cat 5 Cat 5E Cat 6 cable Diagnostic LED Power Power On Green Fast Ethernet Link Green Activity Green blinking Power Requirements Power Consumption Operating Voltage 12 to 48V DC Power consumption max 6 Watts 48V Mechanical Protection class IP67 Installation Wall mount Case Aluminum metal case Dimension 213 6 mm H x 106 0 mm W x 56 5 mm D Weight 1075 g with package E...

Страница 95: ...ctor Cable 10 100 Base TX 2 pair cable Diagnostic LED Power LED Power 1 Power 2 Green Fast Ethernet Port 1 6 Link Green Activity Green blinking Power Requirements Power Consumption Operating Voltage 12 to 48V DC Power consumption max 6 Watts 48V Mechanical Protection class IP68 Installation Wall mount Case Aluminum metal case Dimension 213 6 mm H x 106 0 mm W x 56 5 mm D Weight 1095 g without pack...

Страница 96: ...on with PoE injector 2 x 10 100Base TX Ports auto negotiation speed F H duplex mode and auto MDI MDIX connection Connectors 10 100TX Rugged RJ45 with IP67 grade protection Redundant Power M12 A coded male 5 pin connector Pin assignment Pin1 V1 Pin3 V Pin4 V2 LED Indicators Power 10 100M Link Acts Power Power 1 Power 2 Green Fast Ethernet Link Green Activity Green blinking PoE Power on Blue Cable 1...

Страница 97: ...IP67 IP68 Industrial Ethernet Switch 96 www korenix com EN61000 4 8 PFM Shock IEC60068 2 27 Vibration IEC60068 2 6 Free Fall IEC60068 2 32 ...

Страница 98: ...her Support Korenix Technologies Co Ltd 9F No 100 1 Ming Chuan Rd Shing Tien City Taipei Taiwan Tel 886 2 82193000 Fax 886 2 82193300 Business service sales korenix com Customer service koreCARE korenix com ...