82
Consumer/lamp was already automatically turned on by
the
“AUTO” mode function. The ON time for the connected
consumer can be extended manually. To do so, press the
switch in the supply circuit within 2 seconds as follows:
OFF – ON – OFF –ON
If a lamp is to be connected to the motion switch, it
is switched off for 2 seconds and then switched on
permanently to continuous operation. The maximum ON
time is 8 hours.
Reset manual control to the “AUTO mode” function as
follows:
To do so, press the switch in the supply circuit ON-OFF
within 1 second. If a lamp is to be connected to the motion
switch, it is switched off for 2 seconds and then the motion
switch works in AUTO mode again with the pre-set values.
Once the maximum ON time of 8 hours has expired, the
motion switch automatically switches the consumer off.
Holiday Mode
For this, set the LUX setting to the “Holiday”
3
position.
The LEDs integrated into the motion switch will flash for
10 seconds first, then light up for 10 seconds and then go
out. The motion switch works automatically in “holiday
mode” without taking into account the LUX setting values
3
and time setting values
1
.
The connected lamp is automatically switched on as soon
as a twilight value of less than 50 lux is reached. The switch-
on time fluctuates between 10 minutes and 1 hour within
the next 4 hours.
In order to leave holiday mode, turn the setting knob
3
to a
different position. The LEDs flash for 5 seconds.
3
1
2
GB
Содержание INFRAcontrol R 240
Страница 9: ...9 D 4 3 5 ...
Страница 31: ...31 4 3 5 NL ...
Страница 53: ...53 4 3 5 F ...
Страница 75: ...75 4 3 5 GB ...
Страница 97: ...97 4 3 5 S ...
Страница 112: ...Heinrich Kopp GmbH Alzenauer Str 68 63796 Kahl a Main DEUTSCHLAND www kopp eu DU17100252 ...