Walk Test
The walk test is used to check that the motion switches is
detecting properly at the desired installation location.
To do this, apply the following settings:
• Turn time setting on setting screw
1
to the „test“
position.
• Turn twilight threshold on setting screw
2
to the „+“
position.
• The „twilight threshold“ function is then inactive
3
Install motion switch correctly and connect to the supply
voltage. The device is ready for operation after approx. 90
seconds). During the warm-up phase, the red LED lights up
for approximately 60 seconds.
Begin the walk test from the outside of the probable detec-
tion range and cross the detection area again and again
4
until the motion switch switches.
The connected consumer is switched on. Wait until the
consumer switches off again and repeat the walk test until
you achieve a satisfactory result.