background image

2

TABLE OF CONTENTS

 

 

                                                                                                                         Page 

                   I.                      Introduction                                                                  2 

                  II.                      Incoming Inspection                                                    3 

                 III.                      Product Handling                                                         3 

                 IV.                      Product Identification and Nameplate                         4 

                  V.                      Principles of Operation                                                5 

                 VI.                      Pre-Installation Testing                                                6 

                VII.                      Specific Model Data                                               7 - 9 

                                                Mounting 

                                                Drawings and Dimensions 

                                                Technical Data 

                                                Major Component Replacements 

               VIII.                      Maintenance                                                       10 - 11 

                 IX.                      Trouble Shooting                                                        12 

                  X.                      Warranty                                                                    13 

 

NOTE:

 Wiring Schematics are available on the specific model page of the Kooltronic website.

 

 

I. Introduction

 

 

Kooltronic Air Conditioners are designed to provide a cool, dehumidified environment for 
your electronic components. There are models to fit virtually all sizes and shapes of 
electronic enclosures, in capacities ranging from 1,000 to 30,000 BTU/H. Our 
"closed-loop" design also ensures that your components will not be exposed to hot, dirty 
operating conditions. 
 
This Manual provides you with the necessary general information for properly installing 
and operating standard Kooltronic Air Conditioners. Technical data and mounting 
instructions are presented on pages 7 through 9. 

Содержание TRIMLINE K2A4C1.0NP17L

Страница 1: ...UAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com TRIMLINE NP17 SERIES with Serial Numbers up to M16...

Страница 2: ...age of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all si...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...ect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to the unit ALL MO...

Страница 5: ...ure accumulated on the evaporator coil is collected in the condensate tray and released to the ambient air through the drain tube or the condensate evaporator The heat removed through the evaporator c...

Страница 6: ...be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and co...

Страница 7: ...tween the unit and M TAB before tightening the 10 32 self tapping screws NOTE Do not overtighten these screws 7 Attach overflow drain hose supplied to the drain exit in the side of the unit This hose...

Страница 8: ...ent Air In CONDENSER OUTLET Warm Ambient Air Out WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 12 13 308 1 6 1 4 20 WELD NUTS 2 1 3 4 12 25 311 2 9 00 228 6 17 50 444 5 2 1 3 4 Drawings...

Страница 9: ...mensional changes Switchable Switch is internally mounted for security Rating shown is for operation at maximum ambient temperature 115V 60 Hz and 230V 60 Hz models also perform at full capacity when...

Страница 10: ...nd the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic A...

Страница 11: ...pass valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect r...

Страница 12: ...Control Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Ap...

Страница 13: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: