Technical Data

NP17 Series

                                                                                                     

 

KA4C1.0NP17L                 1000              125/50                   115/100                  60/50             6.7/6.5

59 

KA4C1.0NP17L56             1000              125/50                          115

                50/60*            6.2/6.7

59 

K2A4C1.0NP17L               1000              125/50                   230/200                  60/50                   4.3

59 

K2A4C1.0NP17L5             1000              115/50                          230                       50                    3.5

59 

 

KA4C1.5NP17L                 1500              125/50                   115/100                  60/50             6.7/6.5

59 

KA4C1.5NP17L56             1500              125/50                          115

                50/60*            6.2/6.7

59 

K2A4C1.5NP17L               1500              125/50                   230/200                  60/50                   4.3

59 

K2A4C1.5NP17L5             1500              115/50                          230                       50                    3.5

59 

 

KA4C1.8NP17L                 1800              125/50                   115/100                  60/50             6.7/6.5

59 

KA4C1.8NP17L56             1800              125/50                          115

                50/60*            6.2/6.7

59 

K2A4C1.8NP17L               1800              125/50                   230/200                  60/50                   4.3

59 

K2A4C1.8NP17L5             1800              115/50                          230                       50                    3.5

59 

 

KA4C2.0NP17L                 2000              125/50                   115/100                  60/50             6.7/6.5

59 

KA4C2.0NP17L56             2000              125/50                          115

                50/60*            6.2/6.7

59 

K2A4C2.0NP17L               2000              125/50                   230/200                  60/50                   4.3

59 

K2A4C2.0NP17L5             2000              115/50                          230                       50                    3.5

59

                                            **                Ambient                                                                         **          Approximate 
                                        BTU/H            Temp. °F                                                                   Running         Weight 

Model                               Rating           Max./Min.                  Volts                       Hz               Amps             (lbs.)

 

      

The transformer required to reduce 115 volt supply to 100 volts for 50 Hz compressor 

    operation is externally mounted. Consult KOOLTRONIC for resulting dimensional changes. 

*    Switchable. Switch is internally-mounted for security. 

**  Rating shown is for operation at maximum ambient temperature. 

 115V, 60 Hz and 230V, 60 Hz models also perform at full capacity when operated 

    at 100V, 50 Hz or 200V, 50 Hz respectively.  No transformer is required.

Major Component Replacements 
 

                                                                  KA4C_._NP17              K2A4C_._NP17 

Part                                                             Part Number                  Part Number 

Compressor                                                   0665-102                         0665-104 
Condenser Fan                                              0265-03                           0265-06 
Evaporator Fan                                              0265-03                           0265-06

 

Filter                                                              10871F                            10871F 

NOTE: Part Numbers shown are for 60Hz/1Ø. For all 50Hz consult Kooltronic. 

Units in BOLD are current standard products. Other units are prior product offerings and shown for reference only.

 

Weld-nut mounting method, without M/TAB

Standard Features 

Built-in Condensate Evaporator 
CFC-Free Refrigerant 
Filter 
Low Temperature Control Thermostat 
NEMA 12 Rating Maintained (UL50) 
UL/CUL Listed 

Accessories and Options 

Compressor Short Cycle Protector 
Filter Recoating Adhesive 
High-Capacity Condensate Evaporator 
Internal Corrosion Protection 
Lifting Eyes 
Low Ambient Kit 
Remote Thermostat Relay 
Replacement Filters 
Special materials or finishes  
Special motors, line cords or connectors 
Stainless or Aluminum Shell 
Temperature Alarm 
Weather Protection Kit

Содержание TRIMLINE K2A4C1.0NP17L

Страница 1: ...UAL BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08534 609 466 3400 FAX 609 466 1114 www kooltronic com TRIMLINE NP17 SERIES with Serial Numbers up to M16...

Страница 2: ...age of the Kooltronic website I Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all si...

Страница 3: ...prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before operating this unit all electrical wiring must be checked to assure the proper connection...

Страница 4: ...ect type or amount of refrigerant will adversely affect performance and may damage the unit r Make sure that these parameters are met Failure to do so may result in permanent damage to the unit ALL MO...

Страница 5: ...ure accumulated on the evaporator coil is collected in the condensate tray and released to the ambient air through the drain tube or the condensate evaporator The heat removed through the evaporator c...

Страница 6: ...be delayed until the system pressures rise 10 Operate the air conditioner for approximately ten 10 minutes During this period no unusual noise or vibration should be evident Both the evaporator and co...

Страница 7: ...tween the unit and M TAB before tightening the 10 32 self tapping screws NOTE Do not overtighten these screws 7 Attach overflow drain hose supplied to the drain exit in the side of the unit This hose...

Страница 8: ...ent Air In CONDENSER OUTLET Warm Ambient Air Out WARM AIR RETURN FROM ENCLOSURE COOL AIR OUTLET TO ENCLOSURE 12 13 308 1 6 1 4 20 WELD NUTS 2 1 3 4 12 25 311 2 9 00 228 6 17 50 444 5 2 1 3 4 Drawings...

Страница 9: ...mensional changes Switchable Switch is internally mounted for security Rating shown is for operation at maximum ambient temperature 115V 60 Hz and 230V 60 Hz models also perform at full capacity when...

Страница 10: ...nd the compressor will continue to cycle on and off Continued operation under these conditions will cause damage shorten compressor life and void the warranty A Filter Removal and Service Kooltronic A...

Страница 11: ...pass valve fails it is strongly recommended that the Air Conditioner be returned to Kooltronic for service D Refrigerant Loss Kooltronic Air Conditioners are subjected to a series of tests to detect r...

Страница 12: ...Control Replace Thermostat or Relay Thermostat defective when applicable Failed Compressor Replace Compressor Ice on Evaporator Coil Insufficient Heat Load or Unit Contact Kooltronic Oversized for Ap...

Страница 13: ...eceived by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit in a s...

Отзывы: