The servicing element can be removed upward, in order to gain
access to the flap actuator.
The flap actuator is connected to the fresh air flap by a cap.
It facilitates its removal to the side.
Assembly instructions:
The shaft of the flap actuator and bracket of the flap are fitted to
each other and they can be properly installed only in a specified
position.
Therefore, during installation it is necessary to set the flap
properly on the actuator shaft.
To do this, the flap may be easily repositioned.
The reassembly is carried out in reverse order.
5.3.
Mounting und demounting of control node ATC
– CAN
The WABCO control node is located in the evaporator
part (in driving direction right side) and is mounted on
an electric PCB with a fastening screw.
Unscrew the fastening screw, remove the control unit
(Wabco) upward and disconnect plug connection.
The control node may be replaced with another, which
should be mounted in reverse order.
Servicing element
Flap actuator
Cap of the flap actuator
Servicing element
Cap of the flap actuator
Flap actuator
Air flap
Electric PCB
Wabco control node