Unscrew the oil filler screw. Suck out the old cooling
machine oil with a suitable pump. Fill in new refrigerant
oil and then mount the oil filler screw.
Make sure you use the right sort of refrigerant oil and a new batch. After the refrigerant
oil has been drained, it must be replaced with new oil immediately. Refrigerant oil is
strongly hygroscopic.
Amount refrigerant oil: 1,3 Liter
Tightening torque: Oil filler screw for refrigerant oil 1/4
“ NPTF: 25 Nm
Evacuate the compressor via the service connections
(1) and (5) at the service shut-off valves HD
– high
pressure - (2) and ND
– low pressure - (6).
Refill the evacuated refrigerant amount. Set service
shut-off valves ND (6) and HD (2) of the refrigerant
compressor in „Original Position“ (turn valve counter-
clockwise until stop). Evacuate manometer and de-
mount.
4. Maintenance work on the electrical installations
4.1. Function check of the condenser fans
Switch on the ignition and start the engine.
Press button and take the air conditioner into operation.
Then check the functioning of the condenser fans.
Danger! Risk of injury!
Take special care near hot, rotating or live parts.
Oil filler screw
Oil sight glass
1
6
2
5
Condenser fans