Glider-Mode (Mode 2)
All required properties for electric powered glider airplanes are
preadjusted in this mode.
·
The brake speed is set to average (appx. 0.5 sec) and therefore
suitable for direct drive and many geared drives.
·
The undervoltage cut off is set to 0.8 V/cell and improves the
battery endurance.
·
The overtemperature cut off and the overcurrent cut off is
activated in order to disconnect the motor at over load condition.
·
The RPM limit is set to 50.000 RPM at 4-pole-motors which is
25.000 RPM at 8-pole-motors and 100.000 RPM at 2-pole-
motors.
·
The throttle characteristic is optimized for the use of propellers.
·
The throttle positions are stored during the mode programming,
so the equalizing procedure is no more in use.
·
It’s possible to program a separate motor off position. In this
throttle position the motor is off and the EMF-brake is not
activated. So a folding propeller keeps open and can be used as
an air brake.
·
If no separate motor off position is programmed, the motor off
position is identical to the brake position.