![Kontron MSP8020 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/kontron/msp8020-series/msp8020-series_user-manual_1996308033.webp)
MSP8020 Series User Guide Rev. 1.1
www.kontron.com
// 33
Sensor Name
Event/Reading
type code
Sensor Type
Sensor Specific offset
Event Trigger
Health Status
Bx:
Health Status
7Fh
(OEM Health Status)
24h
(Platform Alert)
00h Status not available in current state
01h Healthy
02h Informational fault
03h Minor fault
04h Major fault
05h Critical fault
Event Data 3:
If the sensor is an aggregation sensor, then event data 2 is used to
return the ID of the first sensor from the aggregation that caused the
fault.
Sensor Aggregation List:
FRU0
ID:
Sensor Name
04h: Temp Brd Inlet
05h: Temp Brd Outlet
07h: Temp BMC
08h: Temp CPU 1
09h: Temp CPU 2
0Eh: Vcc +12.0V SUS
0Fh: Vcc +3.3V SUS
10h: Vcc +1.5V SUS
11h:
Vcc +1.2V SUS
FRU1/2:
ID:
Sensor Name
04h: Bx:IPMI Watchdog
06h: Bx:Vddq
07h: Bx:Vcc +3.3V
08h: Bx:Vcc +3.3V L
09h: Bx:Vcc +1.5V
0Ah: Bx:Vcc +1.05V
0Eh: Bx:PWROK Capt. 1
0Fh: Bx:PWROK Capt. 2