![Kontron MSP8020 Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/kontron/msp8020-series/msp8020-series_user-manual_1996308029.webp)
MSP8020 Series User Guide Rev. 1.1
www.kontron.com
// 29
Table 6: MMC Sensor list
ID
Hex ID
Sensor Name
Sensor Type Code
Reading Type Code
Description
0
0x00
Bx:IPMI Info-1
C0h
(OEM Firmware Info)
70h
(OEM Kontron Internal
Diagnostic)
Internal Management Controller
firmware diagnostic
1
0x01
Bx:IPMI Info-2
C0h
(OEM Firmware Info)
71h
(OEM Kontron Internal
Diagnostic)
Internal Management Controller
firmware diagnostic
2
0x02
Bx:ModuleHotSwap
F2h
Module Hot Swap
6Fh
(Sensor Specific)
Module Hot Swap
3
0x03
Bx:MMC Stor Err
28h
(Management
Subsystem Health)
6Fh
(Sensor Specific)
Management sub-system health
(non volatile memory error)
4
0x04
Bx:IPMI Watchdog
23h
(Watchdog)
6Fh
(Sensor Specific)
IPMI Watchdog
(payload watchdog)
5
0x05
Bx:CPU Reset
CFh
(Board Reset)
03h
(Digital Discrete)
Board reset type and sources
6
0x06
Bx:Vddq
02h
(Voltage)
01h
(Threshold Based)
Voltage on board
Vddq payload power supply
7
0x07
Bx:Vcc +3.3V
02h
(Voltage)
01h
(Threshold Based)
Voltage on board
3.3V payload power supply
8
0x08
Bx:Vcc +3.3V L
02h
(Voltage)
01h
(Threshold Based)
Voltage on board
3.3V L payload power supply
9
0x09
Bx:Vcc +1.5V
02h
(Voltage)
01h
(Threshold Based)
Voltage on board
1.5V payload power supply
10
0x0A
Bx:Vcc +1.05V
02h
(Voltage)
01h
(Threshold Based)
Voltage on board
1.05V payload power supply
11
0x0B
Bx:Power State
D1h
(OEM Power State)
6Fh
(Sensor Specific)
Board Power State