ID
Hex ID
Sensor Name
Sensor Type Code
Reading Type Code
Description
12
0x0C
Bx:Power Good
08h
(Power Supply)
77h
(OEM)
Actual power good status
13
0x0D
Bx:PowerGood Evt
08h
(Power Supply)
03h
(Digital Discrete)
Power good status event that occur
since the last power on or reset
14
0x0E
Bx:PWROK Capt. 1
08h
(Power Supply)
03h
(Digital Discrete)
Latched power rail status
15
0x0F
Bx:PWROK Capt. 2
08h
(Power Supply)
03h
(Digital Discrete)
Latched power rail status
16
0x10
Bx:CPU Status
07h
(Processor)
6Fh
(Sensor Specific)
Processor 0 Status
17
0x11
Bx:ACPI State
22h
(System ACPI
Power State)
6Fh
(Sensor Specific)
Advance Configuration and
Power Interface State
18
0x12
Bx:MMC SEL State
10h
(Event Logging Disable)
6Fh
(Sensor Specific)
Specify the status of the SEL
(Cleared/Almost full/Full)
19
0x13
Bx:Health Status
24h
(Platform Alert)
7Fh
(OEM Health Status)
General health status
(Aggregation of critical sensors)
20
0x14
Bx:POST Value
C6h
(OEM POST Value)
6Fh
(Sensor Specific)
Show current postcode value
(No event generated)