KBox B-201-CFL - User Guide, Rev. 1.0
// 35
7.2.
Minimum System Clearance (Keep out Area)
To provide maximum airflow through and around the box, a minimum distances to the surrounding environment must
be observed. Before installing the KBox B-201-CFL, observe thermal considerations such as keep out areas (Figure 23
and Figure 24).
Leave sufficient clearance (keep out area) to prevent the product from overheating!
To ensure proper operation use the specified recommended keep out areas of :
Top cover: 10 mm (0.394")
Left and right sides: 10 mm (0.394")
Front and rear panel: 10 mm (0.394")
Bottom side: (no restriction)
7.3.
Third Party Components
When configured with third party components such as mPCIe expansion cards, M.2 modules and hard drives
(HDD/SSD), the air temperature inside the system is higher than the ambient temperature. An approximate internal
temperature rise is given.