Introduction
5
CP6930-RM User Guide
www.kontron.com
1.2.3 Temperature
• Operation from 0° C to +55° C inlet air temperature
• Storage temperature range -25° C to +85° C
1.2.4 Humidity
The system is designed to meet Bellcore GR63, Section 4.1.
• Operating: 93% (non-condensing) at 40°C
• Non-Operating: 5%-95% (non-condensing) at 40°C
1.2.5 Altitude
The system is designed to meet the following requirements:
• Operating: 15000 ft, additional cooling might be required above 6000ft
1.2.6 Vibration
The system is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-6 (Sine)
• ANSI/Vita 47-2005, AC1, C1, V1
• Bellcore GR-63, Section 4.4
• 10Hz to 300Hz, Acceleration: 1 g, Test Cycle: 1 oct./min., Cycle Count: 10/axis, 3 axis
• 5 Hz to 100 Hz Power Spectral Density (PSD) = 0.04 g2/Hz
1.2.7 Bump / Shock
The system is designed to meet the following requirements:
• Standard
• DIN/IEC 60068-2-29
• Peak Acceleration: 15 g, Shock Duration: 11 ms half sine, Shock Counts: 500/direction, Recovery Time:
1 s
1.2.8 Safety
The system is designed to meet or meets the following requirements:
• UL 60950-1, 3rd edition (US and Canada)
• EN 60950-1 (Europe)
• LVD 2006/95-EG
Содержание CP6930-RM
Страница 16: ...1 Chapter 1 Introduction www kontron com...
Страница 24: ...9 Chapter 2 Installation www kontron com...
Страница 34: ...19 Chapter 3 Functional Description www kontron com...
Страница 45: ...30 Chapter 4 Software Description www kontron com...
Страница 48: ...1 Appendix A Getting Help www kontron com...