Special Handling and Unpacking 

Instructions

Whenever possible, unpack or pack this product only at EOS/ESD safe work stations. Where a safe work sta-
tion is not guaranteed, it is important for the user to be electrically discharged before touching the product
with his/her hands or tools. This is most easily done by touching a metal part of your system housing.

It is particularly important to observe standard anti-static precautions when changing mezzanines, ROM
devices, jumper settings etc. If the product contains batteries for RTC or memory back-up, ensure that the
board is not placed on conductive surfaces, including anti-static plastics or sponges. They can cause short
circuits and damage the batteries or conductive circuits on the board.

ESD Sensitive Device

Do not handle this product out of its protective enclosure while it is not
used for operational purposes unless it is otherwise protected.

Содержание CP6930-RM

Страница 1: ...www kontron com If it s embedded it s Kontron Kontron User s Guide Document Revision 1 0 Document ID CP6930 RM Issue Date October 2011 CP6930 RM...

Страница 2: ...ved Printed in Canada This user s guide contains information proprietary to Kontron Customers may reprint and use this user s guide in other publications Customers may alter this user s guide and publ...

Страница 3: ...Capability 4 1 2 Technical Specification 4 1 2 1 Mechanics 4 1 2 2 Power Supply 4 1 2 3 Temperature 5 1 2 4 Humidity 5 1 2 5 Altitude 5 1 2 6 Vibration 5 1 2 7 Bump Shock 5 1 2 8 Safety 5 1 2 9 Elect...

Страница 4: ...MP Management 22 3 7 Front Interfaces 22 3 7 1 CP6930 Front Panel Ports 23 3 7 2 CP6930 Front Panel LEDs 25 3 7 3 CP6930 Front Panel Hotswap Switches 26 3 7 4 CP6930 RM 12 Copper Front Interface 27 3...

Страница 5: ...ist of Tables Table 1 1 CP6930 RM Software Specification 7 Table 3 1 SFP and SFP Connector 23 Table 3 5 Health LED state 26 Table 3 6 Activity LED state 26 Table 3 7 CP6930 RM 12 Port Assignment 27 Ta...

Страница 6: ...M Type Label 11 Figure 2 2 CP6930 RM Air Flow 12 Figure 2 3 CP6930 RM12 Fan Module 13 Figure 3 1 Functional Block Diagram CP6930 RM 20 Figure 3 2 Front Panel of the CP6930 23 Figure 3 3 CP6930 RM 12 C...

Страница 7: ...ument Kontron AG reserves the right to change modify or improve this document or the product described herein as seen fit by Kontron AG without further notice Trademarks Kontron AG and the Kontron log...

Страница 8: ...ation by the reader may endanger your health and or result in damage to your material ESD Sensitive Device This symbol and title inform that electronic boards and their compo nents are sensitive to st...

Страница 9: ...omponents which meet the requirements of a SELV circuit safety extra low voltage in accordance with EN 60950 should be connected to the system ports Switching off the device using the power on off but...

Страница 10: ...r optic transmission cables and components can damage your eyes The laser components plugged into the switch are Class 1 laser compo nents Class 1 laser is considered incapable of producing damaging r...

Страница 11: ...etal part of your system housing It is particularly important to observe standard anti static precautions when changing mezzanines ROM devices jumper settings etc If the product contains batteries for...

Страница 12: ...in residential areas is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense English This Class A digital apparatus complies wit...

Страница 13: ...onmental requirements This applies also to the operational temperature range of the specific board version which must not be exceeded If batteries are present their temperature restrictions must be ta...

Страница 14: ...the event of repair refunding or replacement of any part the ownership of the removed or replaced parts reverts to Kontron Modular Computers GmbH and the remaining part of the original guarantee or a...

Страница 15: ...including fan module CP6930 RM User Guide Backplane CP6930 RM User Guide Power Supply 110 230 VAC CP3 SVE P200AC Manual Ethernet Switch CP6930 CP6930 User Guide CP6930 CLI Reference Manual CP6930 FAS...

Страница 16: ...1 Chapter 1 Introduction www kontron com...

Страница 17: ...nterface board either 12 or 24 10 100 1000Base T copper ports Power supply option for second redundant power supply in the CP6930 RM 24 switch 1 1 1 1 19 Inch rack mountable housing 19 Inch 84HP 1U 2...

Страница 18: ...to Unit Computer via RS232 front RJ45 Management connection to Unit Computer using front 10 100 1000Base T management port Management connection to Unit computer via RS232 at J4 FRU data storage seri...

Страница 19: ...a 2U CP6930 RM 24 Ethernet Switch two power supply slots are compliant to hot swap and power sharing when using P47 power supplies from Kontron 1 2 Technical Specification 1 2 1 Mechanics CP6930 RM 1...

Страница 20: ...ft 1 2 6 Vibration The system is designed to meet the following requirements Standard DIN IEC 60068 2 6 Sine ANSI Vita 47 2005 AC1 C1 V1 Bellcore GR 63 Section 4 4 10Hz to 300Hz Acceleration 1 g Test...

Страница 21: ...6 Electro Magnetic Compatibility EMC Requirements for Public Telecommunication Net work Equipment Electromagnetic Compatibility EMC Requirements 1 2 10 WEEE Compliant to Directive 2002 96 EC Waste ele...

Страница 22: ...ic MAC filtering Port Authentication IEEE 802 1X Auto negotiation of speeds and operational mode on all external copper GE in terfaces as well as on all base fabric interfaces Layer 2 multicast servic...

Страница 23: ...nt purposes Persistent storage of configuration across restarts Support for retrieving and installing multiple configurations Support for startup configurations based on the cPCI SGA GA Shelf Geograph...

Страница 24: ...9 Chapter 2 Installation www kontron com...

Страница 25: ...moving the CP6930 The SFP cages have sharp edges which might lead to injuries ESD Equipment Printed circuit boards contain electrostatically sensitive devices Please observe the necessary precautions...

Страница 26: ...let and outlet openings are kept clear and free from any obstructions Leave at least 10 cm approx 4 inch of free space to the front and rear of the CP6930 RM when install ing it from the 19 industrial...

Страница 27: ...s minimal maintenance and care to keep it operating correctly Occasionally wipe the system with a soft dry cloth Remove persistent dirt by use of a soft slightly damp cloth only use a mild detergent K...

Страница 28: ...d as follows 1 Ensure that the safety requirements indicated in chapter 2 1 Safety Requirements are observed 2 Turn the thumbscrew on the front of the fan tray counterclockwise until the indicator has...

Страница 29: ...on it is recommended to turn off power before attempting to replace the switch board To remove the CP6930 switch board proceed as follows 1 Ensure that the safety requirements indicated in chapter 2 1...

Страница 30: ...irements are observed 2 Ensure that no power is applied to the system before proceeding 3 Disconnect any interfacing cables that may be connected to the board 4 Unscrew the front panel retaining screw...

Страница 31: ...pter or an appropri ate RIO module or Fast Ethernet via the front plate RJ45 connector 2 9 1 1 Serial Port The serial port is ready to use offhand without further configuration Port settings are 11520...

Страница 32: ...ress port 23 2 9 2 In Band CLI Access The GbE switch network port in band management access on the CP6930 has no IP address set by default it is necessary to assign an IP address either statically or...

Страница 33: ...nagement interfaces will not be available during this time Are you sure you want to save y n y Config file current startup config created successfully Configuration Saved Ethernet Fabric To access the...

Страница 34: ...19 Chapter 3 Functional Description www kontron com...

Страница 35: ...ck mountable housing 1U or 2U height Ethernet switch CP6930 Internal backplane Front interface board either 12 or 24 10 100 1000Base T copper ports Power supply option for second redundant power suppl...

Страница 36: ...FPs uplink ports are accord ing the Small Form factor Pluggable SFP Transceiver Multi Source Agreement MSA Sept 14th 2000 3 2 Unit Computer and Memory The Unit Computer controls the Ethernet infrastru...

Страница 37: ...rt 3 5 SGA Shelf Global Addressing The backplane provides a DIP switch to allow shelf geografical address SGA settings SGA is used to identify the switches when used in a complex environment Also depe...

Страница 38: ...SGMII support for Copper SFPs in 2 of the 8 front panel uplink ports providing 10 100 1000Base T modes of operation 1x 10 100 1000Base T for Management RJ45 connector 1x RS232 for Management RJ45 con...

Страница 39: ...on com Table 3 2 Front RJ45 Ethernet Connector Contact MDI 1 BI_DA 2 BI_DA 3 BI_DB 4 BI_DC 5 BI_DC 6 BI_DB 7 BI_DD 8 BI_DD Table 3 3 Front RS232 Pin Direction Signal 1 OUT RTS 2 DTR 3 OUT TXD 4 GND 5...

Страница 40: ...terfaces The LED color is green with the following states Off link down On link up but no activity Blinking link up and activity Table 3 4 Serial console terminal cable interface RJ45 Female to DB9 Fe...

Страница 41: ...witch Board supports a Health LED mounted on the front panel The following states are possi ble 3 7 2 2 Activity LED Green LED The position of this LED is near the bottom handle beside the health LED...

Страница 42: ...ts 12 additional 10 100 1000Base T interfaces as shown on the following picture Figure 3 3 CP6930 RM 12 Copper Front Interface The port enumeration is as following Table 3 7 CP6930 RM 12 Port Assignme...

Страница 43: ...ing picture Figure 3 4 CP6930 RM 24 Copper Front Interface The port enumeration is as following Table 3 8 Pin Assignment of the RJ45 Front Connector Contact MDI 1 BI_DA 2 BI_DA 3 BI_DB 4 BI_DC 5 BI_DC...

Страница 44: ...23 In this configuration the corresponding switch inter faces are no longer available on the front interface panel For more information please contact Kontron technical support 0 11 11x 0 12 12x 0 13...

Страница 45: ...30 Chapter 4 Software Description www kontron com...

Страница 46: ...boot loader performs a self test POST In the case that a POST fails a POST error code is written into the postcode register of the onboard CPLD The boot process is not stopped as there are good chance...

Страница 47: ...ssible the PM activates the redundant IPMB bus to re establish system management communication to report the fault The onboard DC voltage current and temperature sensors are monitored by the PM microc...

Страница 48: ...1 Appendix A Getting Help www kontron com...

Страница 49: ...rica EMEA Kontron Canada Inc Kontron Modular Computers GmbH 4555 Ambroise Lafortune Sudetenstrasse 7 Boisbriand Qu bec 87600 Kaufbeuren J7H 0A4 Canada Germany A 1 Returning Defective Merchandise Befor...

Страница 50: ...tal zip code your phone number and your e mail You must also include the serial number of the defective product and a description of the problem A 2 When Returning a Unit In the box you must include t...

Отзывы: