![Kontron CP3005-SA Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/kontron/cp3005-sa/cp3005-sa_user-manual_1996264036.webp)
CP3005-SA – Rev. 0.6 Preliminary
// 36
Bitfield
Description
0 = Disable CPCI reset to board
1 = Enable CPCI reset to board
2
SCOMA
COMA routing selection:
0 = Rear I/O
1 = Extension module
The reset value of the SCOMA bit depends on the board version ordered. If the CP3005-SA is
ordered as a rear I/O version, the reset value is 0. If the CP3005-SA is ordered as a front I/O
version, an automatic switch over to the 8HP extension module is processed per default.
4.3.5.
Device Protection Register (DPROT)
The Device Protection Register holds the write protect signals for non-volatile devices.
Table 17: Device Protection Register (DPROT)
Address
0x284
Bit
7
6
5
4
3
2
1
0
Name
SWP
Reserved
R
000
SFWP
JMP2
BSWP
SSWP
Access
R
R/W
R
R
R/W
Reset
0
0
0
0
0
Bitfield
Description
7
SWP
System write protection status:
0 = Onboard non-volatile memory devices not write protected
1 = Onboard non-volatile memory devices write protected
3
SFWP
SATA Flash module write protection status:
0 = SATA Flash module write protection included in system write
protection
1 = SATA Flash module write protection not included in system write
protection
This bit is read-only if the system write protection bit is activated
(SWP = ’1’).
2
JMP2
System write protection via configuration resistors JMP2:
0 = System not write protected via JMP2
1 = System write protected via JMP2
1
BSWP
System write protection via backplane (SYS_WP#):
0 = System not write protected via backplane
1 = System write protected via backplane
0
SSWP
System write protection via software:
0 = System devices not write protected via software
1 = System write protected via software
Writing a ’1’ to this bit clears it. If this bit is set, it cannot be cleared.