![Kontron CP3003-SA Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/kontron/cp3003-sa/cp3003-sa_user-manual_1996263072.webp)
Installation
CP3003-SA
Page 3 - 4
ID 1052-6929, Rev. 3.0
D R A F T — F O R I N T E R N A L U S E O N L Y
3.2
Initial Installation Procedures
The following procedures are applicable only for the initial installation of the CP3003-SA in a
system. Procedures for standard removal and insertion/removal under power
are found in their
respective chapters.
To perform an initial installation of the CP3003-SA in a system proceed as follows:
1. Ensure that the safety requirements indicated in Chapter 3.1 are observed.
2. Ensure that the board is properly configured for operation in accordance with application
requirements before installing. For information regarding the configuration of the
CP3003-SA refer to Chapter 4. For the installation of CP3003-SA-specific peripheral de-
vices and rear I/O devices refer to the appropriate sections in Chapter 3.
3. To install the CP3003-SA perform the following:
1. Ensure that no power is applied to the system before proceeding.
2. Carefully insert the board into the slot designated by the application requirements for
the board until it makes contact with the backplane connectors.
Warning!
Failure to comply with the instruction below may cause damage to the
board or result in improper system operation.
Warning!
Care must be taken when applying the procedures below to ensure that
neither the CP3003-SA nor other system boards are physically damaged
by the application of these procedures.
Warning!
Even though power may be removed from the system, the CP3003-SA
front panel cables and, when installed, the RIO transition module front pan-
el cables may have power applied which comes from an external source.
In addition, these cables may be connected to devices that can be dam-
aged by electrostatic discharging or short-circuiting of pins.
It is the responsibility of the system designer or integrator to ensure that
appropriate measures are taken to preclude damage to the system or in-
jury to personnel which may arise from the handling of these cables (con-
necting or disconnecting).
Kontron disclaims all liability for damages or injuries resulting from failure
to comply with the above.
Warning!
When performing the next step,
DO NOT
push the board into the back-
plane connectors. Use the ejector handle to seat the board into the back-
plane connectors.
Содержание CP3003-SA
Страница 14: ...Preface CP3003 SA Page xiv ID 1052 6929 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 18: ...Preface CP3003 SA Page xvi ID 1052 6929 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 121: ...CP3003 SA CP3003 HDD ID 1052 6929 Rev 3 0 Page A 1 CP3003 HDD Chapter 1 A D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 135: ...CP3003 SA CP3003 XMC ID 1052 6929 Rev 3 0 Page B 1 CP3003 XMC Chapter 1 B D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 167: ...CP3003 SA CP3003 V ID 1052 6929 Rev 3 0 Page F 1 CP3003 V Chapter 1 F D R A F T F O R I N T E R N A L U S E O N L Y...