![Kontron CP3003-SA Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/kontron/cp3003-sa/cp3003-sa_user-manual_1996263037.webp)
CP3003-SA
Introduction
ID 1052-6929, Rev. 3.0
Page 1 - 13
D R A F T — F O R I N T E R N A L U S E O N L Y
Software
uEFI BIOS
AMI Aptio®, AMI’s next-generation BIOS firmware based on the uEFI Specifi-
cation and the Intel Platform Innovation Framework for EFI.
•
LAN boot capability for diskless systems (standard PXE)
•
Redundant image; fail-safe recovery in case of a damaged image
•
Non-volatile storage of setting in the SPI boot flash (battery only re-
quired for the RTC)
•
Compatibility Support Module (CSM) providing legacy BIOS compatibil-
ity based on AMIBIOS8
•
Command shell for diagnostics and configuration
•
EFI shell commands executable from mass storage device in a Pre-OS
environment (open interface)
Operating Systems
There are various operating systems available for the CP3003-SA. For
detailed information, please contact Kontron.
General
Mechanical
3U, 4 HP, CompactPCI-compliant form factor
Power Consumption
See Chapter 5 for details.
Temperature Range
Operational:
0°C to +60°C
Standard (depending on processor version
and airflow in the system)
-40°C to +85°C
Extended (with Intel® Core™ i7-3517UE,
1.7 GHz ULV processor only)
Storage: -40°C to +85°C
Without hard disk and without battery
Battery
3.0V lithium battery for RTC with battery socket.
Battery type: UL-approved CR2025
Temperature ranges:
Operational (load): -20°C to +70°C typical (refer to the battery manufac-
turer’s specifications for exact range)
Storage (no load): -55°C to +70°C typical (no discharge)
Climatic Humidity
93% RH at 40 °C, non-condensing (acc. to IEC 60068-2-78)
Dimensions
100 mm x 160 mm
Board Weight
313 grams (4 HP CP3003-SA with heat sink, front panel, two 2 GB SODIMM
memory modules, and battery but without SATA Flash module or without
Smart Extension Module respectively)
Note ...
For a description of the additional 8 HP version interfaces, refer to Appendix A,
CP3003-HDD Module and Appendix B, CP3003-XMC Module.
Table 1-1: CP3003-SA Main Specifications (Continued)
FEATURES
SPECIFICATIONS
Note ...
When a battery is installed, refer to the operational specifications
of the battery as this determines the storage temperature of the
CP3003-SA (See "Battery" below).
Note ...
When additional components are installed, refer to their opera-
tional specifications as this will influence the operational and stor-
age temperature of the CP3003-SA.
Note ...
If a Smart Extension Module is installed on the CP3003-SA, the
board exceeds 4 HP.
Содержание CP3003-SA
Страница 14: ...Preface CP3003 SA Page xiv ID 1052 6929 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 18: ...Preface CP3003 SA Page xvi ID 1052 6929 Rev 3 0 D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 121: ...CP3003 SA CP3003 HDD ID 1052 6929 Rev 3 0 Page A 1 CP3003 HDD Chapter 1 A D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 135: ...CP3003 SA CP3003 XMC ID 1052 6929 Rev 3 0 Page B 1 CP3003 XMC Chapter 1 B D R A F T F O R I N T E R N A L U S E O N L Y...
Страница 167: ...CP3003 SA CP3003 V ID 1052 6929 Rev 3 0 Page F 1 CP3003 V Chapter 1 F D R A F T F O R I N T E R N A L U S E O N L Y...