Starting Up
Before using the system, become familiar with the system components and follow the startup instructions below.
Connecting to Power Supply
The AL i.MX6 ULL is connected to a DC main power supply via a Phoenix Contact input power connector on the front panel and
corresponding power cable.
When starting the AL i.MX6 ULL, the functional earth connection must always be made first and
disconnected last. Kontron Electronics recommended that the last connections attached to the system
should be the power cable. Following a proper cabling procedure will prevent a false power-on
condition, which could result in an operational failure.
The AL i.MX6 ULL must be connected to a DC mains power supply complying with the SELV (Safety Extra
Low Voltage) requirements of EN 60950-1 standard. It must be observed that wiring and short-
circuit/overcurrent protection is performed according to the applicable standards, regulations and
respect to the electrical specification of the AL i.MX6 ULL. The disconnecting device (fuse/circuit
breaker) rating must be in accordance with the AL i.MX6 ULL
’s
wire cross-section.
To start the AL i.MX6 ULL, follow the steps below:
1.
Ensure that the DC power source is switched off via a disconnecting device (circuit breaker), to ensure that no power is
flowing from the external DC power source during the connection procedure.
2.
Connect the power connector with wiring (refer to Chapter 6.2: Power Connector and Chapter 6.2.1: Wiring the DC Mating
Power Connector) to the Input power connector located on the front panel, see Figure 8: Front Panel (pos. 1). Pay attention
to the polarity of the connections. For more information on the input power
connector’s polarity, see Chapter
3.
Connect the DC power cable
’s other end
to the DC main power supply.
4.
Switch on the disconnecting device (circuit breaker) to apply voltage to the AL i.MX6 ULL.
Do not disconnect the power from AL i.MX6 ULL while AL i.MX6 ULL is powered up!
Performing a forced shutdown can lead to loss of data or other undesirable effects!
Operating System (OS) and Drivers
The standard AL i.MX6 ULL is fully operational when switched on for the first time with pre-installed OS and drivers. Drivers are
available from Kontron Electronics
’
GitLab Server https://git.kontron-electronics.de.
If ordered without pre-installed OS, before starting the AL i.MX6 ULL the operating system and the appropriate drivers need to be
installed for the ordered system configuration.
Содержание AL i.MX6 ULL
Страница 1: ...USER GUIDE www kontron electronics de 1 AL i MX6 ULL Doc Rev 1 0...
Страница 2: ...AL i MX6 ULL Rev 1 0 www kontron electronics de 2 This page has been intentionally left blank...
Страница 18: ...AL i MX6 ULL Rev 1 0 www kontron electronics de 18 Figure 5 Side views...
Страница 21: ...AL i MX6 ULL Rev 1 0 www kontron electronics de 21 Block Diagram Figure 7 Block Diagram...