6. Product Description
6.11.
M@CII 70/104/150 System Mounting to a Subframe or Panel
The system configurations come in the delivering status with mounting clamps and Allen Screws in order to mount the
system to a subframe or panel (refer to pos. 2, Fig. 39 or pos. 6, Fig. 40, depending on the system ordered).
Fig. 39: Detail with mounting clemps and a subframe
(shown with a M@CII 104 system)
2
2
2
1
6
6
3
2
6
4
4
5
6
3
Fig. 40: Detail with mounting clemps and a subframe
(shown with a M@CII 150 system)
Legend for Fig. 39 and Fig. 40:
1
Enclosure of the 10.4" display
2
Mounting clamp with screw (used for mounting of
M@CII 70/104 into a subframe/panel)
3
CompactFlash™ slot
4
Example of subframe for system installation
5
Enclosure of the 15" display
6
Mounting clamp with screws (used for mounting of the
M@CII 150 into a subframe/panel)
The mounting clamps with screws (supplied), allow the easy and fast mounting of the M@CII 70/104/150 into an
instrument panel or wall panel.
Dimension for:
M@CII 70
M@CII 104
M@CII 150
Rear side enclosure
(W x H x D)
215 x 146.3 x 45.75 [mm]
295 x 234 x 17.25 [mm]
406.4 x 311 x 23.25 [mm]
Cut-Out for Mounting into a Panel
(W x H)
217 x 148 [mm]
8.534 x 5.827 [inch]
297 x 236 [mm]
11.693 x 9.291 [inch]
408 x 313 [mm]
16.063 x 12.323 [inch]
Requirements for Mounting
Metal mounting panel thickness
for proper mounting
1.5 – 6 [mm]
0.059 - 0.236 [inch]
1.5 – 6 [mm]
0.059 - 0.236 [inch]
1.5 – 8 [mm]
0.059 – 0.315 [inch]
Used clamps with screws for
mounting the M@CII
70/104/121/150 device to a
subframe orpanel
4x
8x
8x
Required Tool
Allen Wrench 2 mm
Proper Torque
Tighten the screws with a torque of 0.5 Nm
Mounting Position
Ensure the vertical and horizontal alignment of the system.
Table 6: Requirements for the M@CII 70/104/150 mounting into a subframe/panel