6. Product Description
6.8.2.
Replacing the Lithium Battery
The baseboard is equipped with a Lithium battery.
4
3
2
1
Fig. 36: Detail of opened system – Lithium battery location
1
ETX baseboard
2
Lithium battery
3
ETX® PM 600 module
4
Heat spreader of the ETX module
To replace this battery, please proceed as follows:
1.
Open the unit as described in the 6.8.1 “Configuration of the RS422/RS485 Port” chapter (steps 1-4).
2.
Pull the battery (pos. 2, Fig. 36) outwards.
3.
Position the Lithium battery in the Lithium battery holder with the positive (+) terminal face-up. Gently push the
battery into the holder in as far as it goes.
4.
Make sure that you insert the battery correctly. The plus pole must be on top!
5.
Close the unit as described in the chapter 6.8.1 “Configuration of the RS422/RS485 Port” (step 7 and 8).
The lithium battery must be replaced with an identical battery or a battery type recommended by Kontron Embedded
Computers (Lithium battery 3.0 V for RTC, type: CR2032). The Lithium battery type must be UL listed.
Do not dispose of lithium batteries in domestic waste. Dispose of the battery according to the local
regulations dealing with the disposal of these special materials (e.g. to the collecting points for the
disposal of batteries).
32
M@CII 70/104/121/150 - User’s Manual (V1.00)