32
454200/A
Checking the sensors readings
The TV80 offers the
Measurements
dialog box to identify the latest readings sent by all
the sensors installed and the quality of these readings.
Prerequisites
The TV80 has been set up with its hardware units connected as specified by the relevant
installation instructions.
Procedure
1
On the processor unit desktop, double-click the TV80 icon to start the program.
2
Select the
Setup
icon to open the menu.
3
On the
Setup
menu, select
Installation
.
4
Observe the
I/O Setup
page on the right side of the
Installation
dialog box.
Every interface is presented as a small "block diagram".
5
Select the inspection point at the left
of the “block diagram” you want to
check.
The
Measurements
dialog box opens.
6
Check if the TV80is receiving
information from a specific sensor.
You can see if the TV80 is taking the measurement as a valid value (“y” letter)
or not (“n” letter).
7
Observe the value given for every measurement under
Quality
to verify that each
sensor provides the expected information.