ECON FUNCTION
ECON FUNCTION
1. Start the engine.
2. Set the ECON switch to “ON”.
3. Plug the device into an AC outlet.
4. Make sure the AC indicator light is on.
5. Turn on the electrical device.
FUNCTIONAL DESCRIPTION
OF INVERTER GENERATORS
9
For models with electric start, check if the battery is charged. If necessary, recharge the battery with a
dedicated charger for lithium-ion batteries or start the generator with a manual start and allow it to run
idle while it is recharging.
If during usage of gasoline, need to switch to LPG supply, directly connect the LPG pipe,
turn on the LPG supply, and press the LPG RESET on the control panel to switch to LPG.
If during usage of LPG, need to switch to gasoline, you only need to disconnect the
LPG supply, generator will automatically switch to gasoline оperation, without other
operations
CONNECTION OF GENERATOR WITH BUILT-IN ATS
8
Connection diagrams for generators with built-in ATS can be found in the full electronic version of the
Connection diagrams for generators with built-in ATS can be found in the full electronic version of the
manual.
manual.
Risk of electric shock! Network connection should only be
carried out by a qualified technician.
ATTENTION - DANGER!
It is forbidden to start the generator with the ECONOMY MODE ON. Economy mode
should be turned on only after starting the generator and only with a low load. Failure
to comply with this requirement may result in generator failure and void warranty
repair.
Fuel can be changed without stopping the generator. When switching from gasoline to LPG operation, the
generator may be unstable during the first 2-3 minutes and the low voltage protection may trip. If the red
indicator (overload indicator) lights up in 2-3 minutes after running the generator on LPG when it is running
stable, press the AC Reset BUTTON on a panel of generator to restore voltage supply
The ECON switch must be set to “OFF” to increase engine
speed to nominal. When connecting multiple power
consumers to the generator, be sure to first connect the
one with the highest starting current, and the device
with the lowest starting current should be connected
last.
IMPORTANT!
“ON” MODE
“ON” MODE
When the ECON switch is in the “ON” position, the control unit monitors the engine speed, reducing it
commensurate with the connected load. If the engine speed is not enough to generate electricity to provide
the load, the control unit will automatically increase the engine speed.
As a result, fuel consumption is optimized and noise levels are reduced.
“OFF” MODE
“OFF” MODE
The ECON switch must be set back to “OFF” when using electrical devices requiring a high starting current,
such as a compressor or submersible pump.
The ECON switch must be set back to “OFF” when using
electrical devices requiring a high starting current, such
as a compressor or submersible pump.
IMPORTANT!
konner-sohnen.com
|