Fig. 5
TO START LPG/GASOLINE GENERATOR IN GASOLINE MODE
TO START LPG/GASOLINE GENERATOR IN GASOLINE MODE
(KS 4100
(KS 4100
iiEG, KS 8100
EG, KS 8100iiEG ATSR, KS 2000
EG ATSR, KS 2000iiG S, KS 4000
G S, KS 4000iiEG S, KS 8100
EG S, KS 8100iiEG)
EG)
1. Close the gas valve on the cylinder.
2. Open the vent on the fuel cap to the “ON”
3.
Set the fuel switch to “ON” and close the air choke on the control panel (for model KS 2000iG S).
4. Start the engine by hand or electric start.
5. Open the air choke (for model KS 2000iG S).
For all modifications of models KS 2000i, loosen the 4
screws on the side panel. Loosen drain screw
C
on the
carburetor and let the remaining fuel drain through pipe
D
into the dedicated drip pan. Avoid gasoline leaks.
Tighten up the screw. Install back the generator housing
cover. Start the generator on LPG.
To drain gasoline from the carburetor, turn off the fuel valve and wait until the generator has cooled down
sufficiently. For open frame models, place a drip pan under the carburetor and loosen the drain screw on
the carburetor (Fig. 5). Make sure that no fuel leaks onto the generator. Tighten up the screw again. Start
the generator on LPG according to the instructions mentioned above
Disconnect the load from the generator before changing
fuel. The ECONOMY MODE switch must be in the “OFF”
position.
IMPORTANT!
For model KS 2000iG S: It is recommended to stop the generator before switching from
gasoline to LPG! Gasoline remains in the carburetor make it difficult to start the engine
on LPG. Let the generator run out of gasoline until it stops. To do this, close the fuel valve
with the generator running and wait until the generator stops completely. Then start the
generator on LPG. You can also drain the remaining gasoline from the carburetor before
starting the generator on LPG.
RUNNING GENERATOR ON LPG (KS 4100iEG, KS 8100iEG ATSR,
RUNNING GENERATOR ON LPG (KS 4100iEG, KS 8100iEG ATSR,
KS 8100iEG,
KS 8100iEG, KS 2000iG S,
KS 2000iG S,
KS 4000iEG S)
KS 4000iEG S)
С
KS 2000iG S
D
4. Connect the hose end with the reducer to the gas cylinder (connect hose end
B
to the gas cylinder, as
shown in Fig. 4).
5. Open the gas valve on the cylinder, making sure that no gas is leaking.
6. Press the pressure relief valve on the reducer 2-3 times (see Fig. 4).
7. Turn the Multifunctional engine switch to the “START” position.
8. For manual start, pull the manual starter until a slight resistance is felt, then pull it toward you relatively
sharply. Slowly turn the manual starter by hand, do not release it abruptly. For electric start, press the red
button on the multifunctional engine switch (fig. 1)
9. After starting the engine, turn the Multifunctional engine switch to the “RUN” position (fig. 1).
10. When using for the first time, fill the gas line with gas by turning the key (pressing start button) to the
“OFF” position and slowly pull the starter handle to the full cord length 2 to 3 times (except for models
KS 8100, which do not have a manual start).
For model KS 2000iG S:
Close the air choke (pull the air choke handle) if the generator is not warmed
up.
Set the GASOLINE FUEL SWITCH to the “OFF” position, set the engine start to the “ON” position,
grasp
the starter handle and slowly pull it until resistance is felt. Pull the starter cord to the full length with a sharp
movement. The generator will start. If this is not the case, repeat this action. Slowly turn the manual starter
by hand, do not release it abruptly.
Open the air choke by pushing the air choke handle.
Place the container with gas only vertically, according to
the instruction manual for gas cylinders. The horizontal
placement of gas cylinders leads to hybrid generator
gearbox failure.