COMMISSIONING
COMMISSIONING
1. Fill the crankcase with engine oil. The recommended amount of oil for each model is indicated in the
specification chart.
2. Check oil level with an oil dipstick. It should be between the MIN and MAX marks on the oil dipstick.
3. Check fuel level.
4. Check the air filter for correct installation.
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD
IN THE FIRST 20 OPERATING HOURS OF THE GENERATOR, THE FOLLOWING REQUIREMENTS SHOULD
BE MET:
BE MET:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the
nominal (operating) power of the device.
2. After the first 20 operating hours, be sure to change the oil. It is better to drain oil while the engine is still
hot after operation to ensure quick and complete oil draining.
3. Check and clean the air filter, fuel filter and spark plug.
This material is for informational purposes only and does not constitute a manual for
installing the equipment or connecting it to the mains, but we strongly recommend
that you read the instructions below. Equipment connection must always be carried out
by a certified electrician responsible for the installation and electrical connection of the
equipment according to local laws and regulations. The manufacturer assumes no lia-
bility for improper connection of the equipment or for any material or physical damage
that may result from improper installation, connection or operation of the equipment.
Before starting the generator, connect the ground wire to
the ground terminal.
IMPORTANT!
The generator is shipped with terminals disconnected to prevent battery self-discharge during storage. To
connect the battery terminals of the KS 4000iE S generator, proceed as follows:
1. Open the service cover.
2. Connect the terminals ensuring the correct
polarity (“+” to “+”, “-” to “-”).
1
1
2
2
ENGINE START
ENGINE START
Useful tip: If the engine stalls or does not start, turn
the engine switch to the “ON” position, and then pull
the manual starter. If the oil level indicator flickers for
several seconds, add oil and restart the engine.
IMPORTANT!
konner-sohnen.com
|
13
In the power supply mode, the generator should operate
no longer than 1 minute in the range from nominal to
maximum power.
Standby generators should not run continuously (e.g. by
adding fuel to the tank or connecting a large fuel tank) or
longer than recommended: 4-6 hours for LPG/gasoline or
gasoline generators (depending on load).