232
472405/A
far away from the bridge or any other rooms with wall-to-wall carpets! Whenever
possible, always bring a wristband and ground yourself.
2
Lift the circuit board or module, in its protective antistatic packing bag, out of
the transport box.
3
Place it in a stable position on the workbench.
4
Inspect the unit for damage.
a
If a unit has been damaged, prepare an inspection report stating the condition
of the unit and actions taken.
b
Describe the damage, and collect photographic evidence if possible. Return
the inspection report to Kongsberg Maritime as soon as possible.
5
Assuming all is well, open the bag and remove the unit.
Note
Do not break the seal to open a printed circuit board, an electronic module or a unit
before it shall be used. If the unit is returned with a broken seal we will assume that
it has been used. You will then be billed accordingly.
6
Take out and keep the documentation.
You will need the documentation if the item shall be returned to us.
7
Remove any packing and desiccant material that may be found inside the shipping
container or bag.
8
Keep the protective antistatic packing bag for future use.
Related topics
Transporting Kongsberg Maritime equipment, page 217
Packing instructions for storage or shipping, page 227
Returning a printed circuit board or an electronic module to Kongsberg Maritime,
page 232
About Electrostatic Discharge (ESD), page 234
Returning a printed circuit board or an electronic module
to Kongsberg Maritime
If you wish to return a printed circuit board or an electronic module to Kongsberg
Maritime - either operational or defective - certain rules apply.
Prerequisites
For correct and safe handling of printed circuit boards and electronic modules, you need
a suitable working area. The working area must be covered by an approved conductive
service mat that has a resistance of between 50 kΩ and 2 MΩ, and is connected directly
to a reliable earth point via its earthing cord. You - and all other service personnel
KONGSBERG EM 2040 MKII Installation Manual
Содержание EM 2040 MKII
Страница 8: ...8 472405 A KONGSBERG EM 2040 MKII...
Страница 92: ...92 472405 A Related topics List of cables page 101 KONGSBERG EM 2040 MKII Installation Manual...
Страница 107: ...472405 A 107 Related topics Cable plan Hydrographic Work Station page 100 Cable layout and interconnections...
Страница 177: ...472405 A 177 338208 RX transducer outline dimensions 0 7 degrees Drawing file...
Страница 178: ...178 472405 A 338207 TX transducer outline dimensions 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 179: ...472405 A 179 337805 TX transducer outline dimensions 0 4 degrees Drawing file...
Страница 180: ...180 472405 A 353631 Transducer mounting plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 181: ...472405 A 181 355913 Transducer mounting plate 0 4 x 0 7 degrees Drawing file...
Страница 182: ...182 472405 A 359252 Baffle plate 0 7 x 0 7 degrees KONGSBERG EM 2040 MKII Installation Manual...
Страница 183: ...472405 A 183 385422 Processing Unit dimensions Drawing file...
Страница 184: ...184 472405 A 424178 Portable Processing Unit dimensions KONGSBERG EM 2040 MKII Installation Manual...
Страница 185: ...472405 A 185 464618 HWS dimensions MC330 Rack model Drawing file...
Страница 186: ...186 472405 A 475694 HWS dimensions MC330 Desktop model KONGSBERG EM 2040 MKII Installation Manual...
Страница 187: ...472405 A 187 370275 Remote Control Unit K REM dimensions Drawing file...
Страница 188: ...188 472405 A 373962 Remote Control Unit K REM wiring diagram KONGSBERG EM 2040 MKII Installation Manual...
Страница 247: ......
Страница 248: ...2021 Kongsberg Maritime...